Kenmore 153.320661 Water Heater User Manual


 
Start Up Conditions
TNERMAL EXPANSmON
Property Damage Hazard
° Avoid water heater damage.
o Install thermal expansion tank or device if necessary.
oContact qualified installer or service agency.
NOTE: Expansion tanks are preocharged with a 40 psi air
charge. Bfthe inlet water pressure is higher than 40 psi, the
expansion tank's air pressure must be adjusted to match
that pressure, but must not be higher than 80 psi.
Water supply systems may, because of such events as high
line pressure, frequent cut-offs, the effects of water hammer
among others, have installed devices such as pressure
reducing valves, check valves, back flow preventers, etc._to
control these types of problems. When these devices are not
equipped with an internal by-pass, and no other measures are
taken, the devices cause the water system to be close& As
water is heated, it expands (thermal expansion) and closed
systems do not allow for the expansion of heated water.
The water within the water heater tank expands as it is heated
and increases the pressure of the water system. If the relieving
point of the water heater's temperature-pressure relief valve is
reached, the valve wil! relieve the excess pressure. The
temperatureopressure relief valve is not intended for the
constant relief of thermal expansion. This is an unacceptable
condition and must be corrected.
It is recommended that any devices installed which could create
a closed system have a by-pass and/or the system have an
expansion tank to relieve the pressure built by thermal
expansion in the water system. Thermal expansion tanks are
available from Sears stores and through the Sears Service
Centers. Contact the local plumbing inspector, water supplier
and/or the Sears Service Center for assistance in controlling
these situations.
Therma! Expansion Tank Specifications
Model
Number
153.331020
153.331050
Tank Dimensions
Capacity in inches
in Gallons _m Length
2 8 (203 ram) 12-3/4 (323 ram)
5 11(279 mm) 14-3/4 (375 mm)
Pipe
Fitting
On Tank
3/4" Mate
3/4" Mate
WATER HEATER (3)
COLD WATER PRESSURE
0NLET FITTING REDUCING
VALVE WITH
BY-PASS
{2)
PRESSURE GAUGE
ruNLETCOLD
WATER SHUT-OFF
RECOMMENDED mNSTALLATION
IVERTICAL MOUNTING)
WATER HEATER
COLD WATER
INLET FITTING
FLOOR, CEILING JOIST, ETC.
_ STRAPPING (3)
PRESSURE
REDUCING
_%"(1) VALVEWITHBY=PASS
EXPANSmON /
TANK
!2) / f
PRESSUREGAUGE #1LETCOLD
WATER SHUT-OFF
ALTERNATE RECOMMENDED INSTALLATION
{HORIZONTAL MOUNTING)
FIGURE 43.
STRANGE SOUNDS
Possible noises due to expansion and contraction of some
metal parts during periods of heat-up and cool-down do not
represent harmful or dangerous conditions.
Operationa_ Conditions
SMELLY WATER
Expansion Tank Sizing Chart
Water Heater Capacity (Gallons)
Expansion
Tank
Capacity
Needed
h[et*
Water
Pressure
40psi
50psi
60psi
70psi
80psi
E
30 40 50 66 82
2 2 2 5 5
2 2 2 5 5
2 2 5 5 5
2 2 5 5 5
2 5 5 5 5
In each glass-lined water heater there is installed one anode
rod (see parts section) for corrosion protection of the tank.
Certain water conditions will cause a reaction between this
rod and the water. The most common complaint associated
with the anode rod is one of a "rotten egg smell'L This odor is
derived from hydrogen sulfide gas dissolved in the wateE The
smell is the result of four factors which must all be present for
the odor to develop:
A A concentration of sulfate in the supply water.
B. Little or no dissolved oxygen in the water.
*Highest recorded inlet water pressure in a 24 hour period or
regulated water pressure.
C. A sulfate reducing bacteria within the water heater. (This
harmless bacteria is nomtoxic to humans.)
23