Installation Instructions (cont'd)
Installation Checklist
Whether or not the element conversion is made, the model
rating plate must be marked. Using a hard point ink pen,
check the appropriate block within the model rating plate,
which is located adjacent to the lower access panel.
Is the fuse or circuit breaker size correct as shown in the chart
in the "Product Specifications" section?
Are the wires from the circuit breaker or fuse service to the
water heater's junction box on the correct wire size (gauge) as
shown in the chart m the Product Speclficauons section.
Is the new temperature-pressure relief valve properly
installed, and piped to an adequate drain? See "Temperature-
Pressure Relief Valve" section.
ls the water heater completely filled with water? See "Filling
the Water Heater" instructions in the "Installation
Instructions" section.
Will a water leak damage anything? See "Facts to Consider
About the Location sectmn.
Are the cold and hot water lines connected to the water heater
correctly? See "Water Piping" instructions in the "Installation
Instructions" section.
Is there adequate clearance for maintenance around the water
heater?
Do you need to call your electric company to check your
wiring?
HOT COLD
TEMPERATURE-
PRESSURE
RELIEFVALVE
_DISCHARGE PIPE
(Do not cap or plug)
I6 AIR GAP
De
FLOOR DRAIN
MODEL RATING PLATE