Installation Instructions (cont'd)
Converting the Lower
Element (cont'd)
9. Tighten terminals 2 and 3 to ensure proper electrical
connection.
AWARNING_
Failure to lighten terminal screws can cause a fire which
can result in DEATH, SERIOUS BODILY INJURY, OR I
PROPERTY DAMAGE. 1
10. Replace terminal cover on the thermostat, making sure the
notch is in place over the tab.
12. The adjustment dial has a "D" shaped opening that matches
a "D" shaped shaft on the thermostat. Align the opening in
the dial to the shaft and gently push the dial onto the shaft.
13. Replace the access panel.
AWARNING
Make sure the thermostat is flush against the tank, the
terminal cover is in place, and the insulation is replaced.
Failure to do so can result in DEATH, SERIOUS BODILY
NJURY, OR PROPERTY DAMAGE.
l 1. Replace the insulation block so that it completely covers the
thermostat and element.
14. Complete wiring to the water heater, or if completed, turn
"ON" electric power to the water heater after filling the
tank with water.
A CAUTION
Never use this water heater unless it is completely full ofl
water. To prevent damage to the tank and heating ele-
ment, the tank must be filled with water. Water must J
flow from the hot water faucet before turning "ON"
power. I
12