Kenmore 116.31412 Vacuum Cleaner User Manual


 
TO CLEAN AGITATOR
NOTE: In order to keep cleaning efficiency
high and to prevent damage to your vacu-
um, the agitator must be cleaned every time
the belt is changed.
The agitator must be cleaned according to
the following schedule:
Vacuum Use
HEAVY
(used daily)
MODERATE
(used 2-3 times/week)
Clean Agitator
every week
every month
LIGHT
(used 1 time/week)
every 2months
Remove ant dirt or derbris in the belt path
area or in the agitator area.
Exploded View - Agitator
Assembly
Carefully remove the brush end caps and
remove any string or debris located on the
agitator assembly, end caps, washers or
agitator shaft.
End
CiP Agitator Unit
Wa!her
End Cap
NOTE: Replace
the end caps. See
the exploded view
for correct assem-
bly.
TO REPLACE BELT
Make sure that the carpet/bare floor selec-
tor is in the carpet position.
Loop the new belt on the motor shaft.
Motor
Shaft
Belt Carpet/Bare Floor
Pulley Belt Selector Shaft
BELT ROUTING
Correct Routing of Belt
(Selector in CarpetPosition)
Agitator Motor
Carpet/Bare Floor Shaft
Selector Shaft
Incorrect Routing of Belt
(Belt on Selector Shaft)
"_" _,Carpe t/Bare
' Floor Pedal
Agitator Motor
Carpet/Bare Floor Shaft
Selector Shaft
Incorrect Routing of Belt
(Selector in Bare Floor Position)
Agitator Belt Carpet/Bare Floor
Selector Shaft
17