Kenmore 116.25914 Vacuum Cleaner User Manual


 
CANISTER CARE
For best cleaning results, the dust bag
should be changed often. The electronic
performance indicator will come on when
the bag needs to be changed or the airflow
is blocked.
NOTE: See PARTS AND FEATURES for
Bag Number.
1. Unplug cord from
wall outlet.
2. Remove hose
from canister.
3. Pull hood release
out and up, then lift
canister hood.
4. Disengage
cardboard tab from
red bag mount by
pulling away and
lifting up.
5. Pull bag out of
the red bag mount.
Mount
6. Check the
motor safety
filter and
replace, if
necessary.
7. The red bag mount will flip forward after
removing bag. This will prevent the lid from
closing until a new bag is installed.
Note: DO NOT bend or crease the middle
of the cardboard when installing the bag
into the bag mount slots.
8. Rotate red bag
mount down and
m
install bag into
slots per
instructions
pushing down until _
the cardboard tab
locks into position
and the holes align. Tuck the bag securely
into the bag cavity so that none of it is able to
be pinched by the hood.
9. Close and latch canister hood.
10. Reinstsllhose.
11. Plug cord into wall outlet.
CAUTION
NEVER REUSE A DUST BAG.Very fine
materials, such as carpet freshener, face
powder, fine dust, plaster, soot, new
carpet lint, etc. can clog the bag and
cause it to burst before it is full and may
cause damage to vacuum motor. Change
bag more often when vacuuming these
materials.
1. Unplug cord from wall outlet. DO NOT
drip water on vacuum cleaner.
2. Clean exterior using a clean, soft cloth
that has been dipped in a solution of mild
liquid detergent and water, then wrung dry.
Wipe dry after cleaning.
3. To reduce static electdcity and dust build-
up, wipe outer surface of vacuum cleaner
and attachments.
CAUTION
Do not use attachments if they are wet.
Attachments used in dirty areas, such
as under a refrigerator, should not be
used on other surfaces until they are
washed. They could leave marks.
15