Karcher BDP 50 Vacuum Cleaner User Manual


 
16 English
ƽ Danger
Risk of injury. Pull the plug from the mains
before carrying out any tasks on the appli-
ance.
Î Check the mains connection cable for
damages. Replace the defective mains
cable.
Î Check filled level of the filter bag; re-
place, if required.
To ensure a reliable operation of the appli-
ance maintenance contracts can be con-
cluded with the competent Kärcher sales
office.
ƽ Danger
Risk of injury. Pull the plug from the mains
before carrying out any tasks on the appli-
ance.
In case of faults that cannot be remedied us-
ing the table below please contact the cus-
tomer service.
Maintenance and care
Maintenance contract
Faults
Fault Remedy
Appliance
does not start,
indicator lamp
"main power"
does not illumi-
nate.
Check fuse in the build-
ing, main cables, plugs
and socket. If the fuse in
the building is tripped
several times, contact
customer service.
Appliance
does not start,
indicator lamp
"main power" is
illuminated.
Properly operate the re-
lease, see "switching on
the appliance“.
Put the handle into the
working position. With
the handle in the upright
position, the appliance
cannot be started.
Check for correct con-
nection of the connector
in the control line.
Appliance vi-
brates strongly
Check pad attachment
Clean the pad
Replacing the pad
Pad does not
turn
Check if foreign bodies
are blocking the pad; re-
move the foreign bodies
if required.
Accessories
Description Part no.:
Pad, soft, nature 6.371-146.0
Pad, soft, biege 6.369-468.0
Pad, medium soft, red 6.369-079.0
Pump spray bottle, 1 liter 6.394-409.0
Pre-spraying unit 6.670-020.0
Detergent
Description Part no.:
Spray Cleaner RM 748, 10
liters
6.295-162.0