Jotul GF 100 DV II, GF 200 DV II Electric Heater User Manual


 
15
GF 100 DV II Nordic QT
GF 200 DV II Lillehammer
Tools required:
1/2” open ended wrench or deep-well socket, Torx T20
or slotted screwdriver, 4 mm allen wrench.
Conversion Kit Contents:
1, regulator tower labeled for propane
3, regulator tower screws
1, burner orifice (GF 100: #48 for NG, #56 for LP)
(GF 200: #46 for NG, 1.20 mm for LP)
1, pilot orifice (#51 for NG, #30 for LP)
Label A - to be completed and applied to
the back of the stove
Label B - apply to the stove’s Rating Plate
Small valve label - apply to valve body
Conversion instructions are also shipped in the stove
with the conversion kit.
Mobile Home Installation
These appliances can be installed for use in a mobile
home in the U.S. and Canada provided:
1. The stove is secured to the floor of the mobile home.
Use the Jøtul Floor Bracket Kit appropriate for your
stove’s leg; see the Accessories listing on p. 29.
2. Provision must be made to secure an electrical ground
between the stove and the mobile home chassis.
3. The stove is installed in accordance with Title 24 CFR,
Part 3280- Manufactured Home Construction and
Safety Standard, in the U.S. In Canada, comply with
CSA Z240.4, Gas Equipped Recreational Vehicles and
Mobile Housing.
4. Always contact your local officials about installation
restrictions and requirements in your area.
THIS APPLIANCE MAY BE INSTALLED AS AN
OEM INSTALLATION IN A MANUFACTURED
(MOBILE) HOME AND MUST BE INSTALLED IN
ACCORDANCE WITH THE MANUFACTURER’S
INSTRUCTIONS AND THE MANUFACTURED
HOME CONSTRUCTION AND SAFETY STAN-
DARD, TITLE 24 CFR, PART 3280. THIS APPLI-
ANCE IS ONLY FOR USE WITH THE TYPE OF
GAS THAT IS INDICATED ON THE STOVE’S
RATING PLATE. A GAS CONVERSION KIT IS
PROVIDED WITH THE NORDIC QT DIRECT
VENT GAS STOVE.
THIS APPLIANCE MAY BE INSTALLED IN AN
AFTERMARKET PERMANENTLY LOCATED,
MANUFACTURED (MOBILE) HOME, WHERE
NOT PROHIBITED BY LOCAL CODES.
CET APPAREIL PEUT ETRE INSTALLE DANS
UN MAISON PREFABRIQUEE (MOBILE) DEJA
INSTALLEE A DEMEURE SI LES REGLEMENTS
LOCAUX LE PERMETTENT. CET APPAREIL
DOIT ETRE UTILISE UNIQUEMENT AVEC LES
TYPES DE GAS INDIQUES SUR LA PLAQUE
SIGNALETIQUE. NE PAS L’UTILISER AVEC
D’AUTRES GAS SAUF SI UN KITDE CONVER-
SION CERTIFIE EST INSTALLE.
Fuel Conversion
Your gas stove is shipped from the factory equipped to
burn NATURAL GAS only. If PROPANE gas is to be used as
fuel, the appliance must first be converted for use with
propane.
GF100 DV II Nordic QT: Use Propane Conversion Kit
155628, supplied with the appliance.
GF200 DV II Lillehammer: Use Propane Conversion Kit
155626, supplied with the appliance.
WARNING:
THE CONVERSION KIT IS TO BE
INSTALLED BY AN AUTHORIZED JØTUL
SERVICE TECHNICIAN IN ACCORDANCE
WITH THE MANUFACTURER’S
INSTRUCTION AND ALL CODES AND
REQUIREMENTS OF THE AUTHORITY
HAVING JURISDICTION. FAILURE TO
FOLLOW THESE INSTRUCTIONS COULD
RESULT IN SERIOUS INJURY OR
PROPERTY DAMAGE. THE QUALIFIED
AGENCY PERFORMING THIS WORK
ASSUMES RESPONSIBILITY FOR THIS
CONVERSION.
IN CANADA:
THE CONVERSION SHALL BE CARRIED
OUT IN ACCORDANCE WITH THE RE-
QUIREMENTS OF THE PROVINCIAL AU-
THORITIES HAVING JURISDICTION AND
IN ACCORDANCE WITH THE REQUIRE-
MENTS OF THE CAN1-B149.1 AND .2
INSTALLATION CODE.