Jotul GF100 DV Electric Heater User Manual


 
7
Stove and Vent Clearance
Requirements
Minimum Clearances from the Stove to Combustibles:
See figs. 2-4.
Rear: 0” (0 mm)
Ceiling: 25” (635 mm)
Corner: 2” (50 mm)
Right Side: 3” (76 mm)
Left Side: 10” (254 mm) - for access to Lighting Instruction plate
Minimum Clearances from the Vent Pipe to Combus-
tibles:
Horizontal Run:
Off the top of the pipe 2” (50 mm)
Off the sides and bottom 1” (25 mm)
Vertical Run:
All sides 1” (25 mm)
Alcove Installation
Maximum Alcove Depth: 24” (610 mm)
Minimum Alcove Width: 34” (864 mm)
Minimum Ceiling Height: 47” (1094 mm)
* Allow 10” on left side of the appliance for complete
access to the lighting instructions and control valve.
CLEARANCE TO REAR WALL IS= (0”) ZERO CLEARANCE
3”
(80 mm)
Right Side
Figure 3. Parallel Installation Clearances.
2”
50 mm
2”
50 mm
Figure 4. Corner Clearances.
10” *
(250 mm)
Left Side
1” deep trim
must be 4”
(102 mm)
off the top
of the stove.
Figure 2. Mantel and Trim Clearance
specifications.
24”or greater
Mantel Depth or Ceiling
12” or less
6” or less
4”or less
6”
152 mm
9”
229
mm
16”
406 mm
25”
635 mm