18
Optional Wall Thermostat or
Remote Control
Use only a 750 millivolt DC two-wire circuit thermostat
with this appliance. The thermostat should be placed in
the same room as the heater, typically 5 feet off the
floor. Avoid drafty areas or any area that may affect the
accuracy of the thermostat.
The thermostat should be connected to the Nordic
QT using a minimum of 16 gauge wire with a maximum
length of 35 feet of wire.
Connect the two thermostat wire leads to the two
lower terminals on the terminal block located directly
above the ignitor button. Do not overtighten the
connections. IT IS NOT NECESSARY TO DISCONNECT
ANY OTHER WIRES. See Fig. 23.
For thermostatic operation, the On/Off/T-Stat
switch on the back of the stove must be in the T-stat
position, and the pilot light must be running, as it is the
power source for the thermostat.
At the thermostat, the two wires should be con-
nected to the two connection screws on the thermostat
base plate per the manufacturer’s instructions.
Remote Control
When using a remote, the remote receiver should be
wired to the terminal block the same way the thermo-
stat would be. See the instructions above.
Follow the operating instructions included with the
Remote Control unit.
CAUTION:
LABEL ALL WIRES PRIOR TO DISCONNECTION
WHEN SERVICING THE CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER OR DANGEROUS
OPERATION. ALWAYS VERIFY PROPER OPERA-
TION AFTER SERVICING THE APPLIANCE.
Log Set Installation
The Nordic QT is equipped with a one piece log set and is
packaged in bubble wrap inside the firebox. The log set
must be removed from the packaging and arranged in
the unit prior to start up of the gas stove. Do not handle
the log set with your bare hands. Always wear gloves to
prevent skin irritation from the ceramic fibers.
To install the log set, remove the packaging and
place the log set inside the firebox, centered and pushed
completely back against the rear wall of the stove.
See fig. 24.
Also included is a bag of ember stones that will
simulate glowing embers when the burner is operating.
These should be broken into pea-sized pieces and spread
equally spaced across the screen on the burner tube.
NOTE: All the embers do not have to be used.
THE CERAMIC FIBER LOGS AND GLOWING EMBERS CAN
IRRITATE YOUR SKIN. GENTLY WASH YOUR HANDS WITH
WARM SOAPY WATER AFTER HANDLING THE LOGS.
Figure 23. Accessory wiring diagram.
Figure 24. Center the Log Set within the firebox.
Place Ember
stones on screen
Pilot Assembly
Location
TERMINAL
BLOCK
VALVE
THERMOPILE
OPTIONAL
THERMOSTAT
or
REMOTE
CONTROL
TH
TP
TH
TP
ROCKER
SWITCH
ON
OFF
STAT