364861-UIM-H-0712
20 Johnson Controls Unitary Products
FIGURE 27: Horizontal Left Configuration
HORIZONTAL - LEFT
INDUCER ROTATED
HORIZONTAL - LEFT
INDUCER AS RECEIVED
(Except for 130K Model)
AIRFLOW
AIRFLOW
Move pressure switch hose
to this position.
NOTE: May require the longer
hose that is provided with
wider cabinets
Move rain gutter hose to this position
NOTE: May require hose extension
that is provided with wider cabinets
Move rain gutter
hose to this position
Move pressure switch
hose to this position.
NOTE: May require
the longer hose that
is provided with
wider cabinets
Change condensate drain
connection to the 90° fitting provided
Move condensate
drain hose to this position
Move rain gutter hose to
this position
NOTE: May require hose
extension that is
provided with wider
cabinets
Move
condensate
drain hose to
this position
Change condensate
drain connection to
the 90° fitting provided
When drain hose routing changes are required, be sure to cap all un-used openings.
If rerouting hoses - excess length should be cut off so that no sagging loops will collect
and hold condensate, which will cause the furnace to not operate.
1
2
3
4
5
3
4
1
2