Johnson Controls TCGD30 Air Conditioner User Manual


 
415571-UTG-C-0309
4 Johnson Controls Unitary Products
— = Not applicable.
COOLING CAPACITY - With Air Handler Coils
UNIT
MODEL
AIR HANDLER
COIL
MODEL
1
COOLING
MODEL W
RATED
CFM
NET MBH
SEER EER
TOTAL SENS.
13 SEER AC WITH MA
TCGD30S4(3,4)S1
MA12B 17 FC/MC35B 1000 29.0 21.0 13.00 11.00
MA12B 17 FC/MC43B 1000 29.0 21.0 13.00 11.00
TCGD36S4(3,4)S1
MA12B 17 FC/MC43B 1200 35.0 24.8 13.00 11.00
MA14D 24 FC/MC48D 1200 35.0 24.8 13.00 11.00
TCGD42S4(3,4)S1
MA16C 21 FC/MC43C 1400 42.0 29.2 13.00 11.00
MA14D 24 FC/MC48D 1400 42.0 29.2 13.00 11.00
MA16C 21 FC/MC48C 1400 42.0 29.2 13.00 11.00
TCGD48S4(3,4)S1
MA16C 21 FC/MC48C 1600 48.0 34.4 13.00 11.00
MA20D 24 FC/MC48D 1600 48.0 34.4 13.00 11.00
MA16C 21 FC60C 1600 48.0 34.4 13.00 11.00
MA20D 24 FC/MC60D 1600 48.0 34.4 13.00 11.00
TCGD60S4(3,4)S1
MA20D 24 FC/MC60D 1800 57.0 38.5 13.00 11.00
MA20D 24 FC/MC62D 1800 57.0 38.5 13.00 11.00
13 SEER AC WITH AHP / SHP / AHX / F*FP
TCGD30S4(3,4)S1
AHP30 17 1015 29.0 21.0 13.00 11.00
AHP36 21 1040 29.0 21.0 13.00 11.00
AHX30 17 - 1025 29.4 22.2 14.00 11.75
AHX36 21 - 1005 30.0 22.3 14.50 12.00
F4FP040 18 1050 29.0 21.0 13.00 11.00
F6FP030 17 - 1035 29.2 21.6 13.50 11.40
F6FP036 21 - 980 29.4 21.4 14.00 12.00
TCGD36S4(3,4)S1
AHP36 21 1235 35.0 24.8 13.00 11.00
AHP42 21 1255 35.0 24.8 13.00 11.00
AHX36 21 - 1225 35.2 25.0 13.50 11.50
AHX42 21 - 1190 35.4 25.2 14.00 11.80
F5FP048 24 1235 35.0 24.8 13.00 11.00
F6FP042 21 - 1290 35.8 25.8 13.50 11.50
TCGD42S4(3,4)S1
AHP42 21 1485 41.0 29.2 13.00 11.00
AHX42 21 - 1395 42.0 29.9 14.50 12.00
F5FP048 24 1455 41.0 29.2 13.00 11.00
F6FP042 21 - 1455 42.0 30.1 14.00 11.75
F6FP048 24 - 1380 41.5 29.4 13.50 11.70
TCGD48S4(3,4)S1
AHP/SHP48 24 1675 48.0 34.4 13.00 11.00
AHP/SHP60 24 1600 48.0 35.0 13.50 11.00
AHX48 24 - 1660 48.0 35.4 13.50 11.50
F5FP048 24 1600 48.0 34.4 13.00 11.00
F5FP060 24 1600 48.0 34.4 13.00 11.00
F6FP048 24 - 1625 47.0 34.8 13.00 11.30
TCGD60S4(3,4)S1
AHP/SHP60 24 1850 57.0 38.5 13.00 11.00
AHX60 24 - 1905 58.5 40.0 13.50 11.50
F5FP060 24 1900 57.0 38.5 13.00 11.00
F6FP060 24 - 1710 57.5 39.0 13.50 11.50
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.