Johnson Controls TCGD18 THRU 60 Air Conditioner User Manual


 
359319-BTG-G-0509
6 Johnson Controls Unitary Products
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils
UNIT MODEL
FURNACE**
COIL
MODEL
COOLING
CFM RANGE
(Min.-max.)
W
RATED
CFM
NET MBH
SEER
1
EER
TOTAL SENS.
TCGD18S41S1(H)
450 - 750 14,17 FC/MC/PC18 600 17.5 12.9 13.00 11.00
450 - 750 14 HC18 600 17.5 12.9 13.00 11.00
450 - 750 14,17 UC18 600 17.5 12.9 13.00 11.00
TCGD24S41S1(H)
600 - 1000 14 FC/MC/PC32 800 24.0 16.7 13.00 11.00
600 - 1000 17,21 FC/MC/PC35 800 24.0 16.7 13.00 11.00
600 - 1000 14,17,21 FC/MC/PC36 800 24.0 16.7 13.00 11.00
600 - 1000 14 FC/MC/PC37 800 24.0 16.7 13.00 11.00
600 - 1000 17,21 FC/MC/PC43 800 24.0 16.7 13.00 11.00
600 - 1000 14 HC30 800 24.0 16.7 13.00 11.00
600 - 1000 17 HC36 800 24.0 16.7 13.00 11.00
600 - 1000 21 HC42 800 24.0 16.7 13.00 11.00
600 - 1000 14,17,21 UC36 800 24.0 16.7 13.00 11.00
TCGD30S41S1(H)
800 - 1200 14 FC/MC/PC32 1000 29.0 21.0 13.00 11.00
800 - 1200 17,21 FC/MC/PC35 1000 29.0 21.0 13.00 11.00
800 - 1200 14 FC/MC/PC37 1000 29.0 21.0 13.00 11.00
800 - 1200 17,21 FC/MC/PC43 1000 29.0 21.0 13.00 11.00
800 - 1200 17 HC36 1000 29.0 21.0 13.00 11.00
800 - 1200 21 HC42 1000 29.0 21.0 13.00 11.00
TCGD36S41S1(H)
1000 - 1400 14 FC/MC/PC37 1200 35.0 24.8 13.00 11.00
1000 - 1400 17,21 FC/MC/PC43 1200 35.0 24.8 13.00 11.00
1000 - 1400 21,24 FC/MC/PC48 1200 35.0 24.8 13.00 11.00
1000 - 1400 21 HC42 1200 35.0 24.8 13.00 11.00
1000 - 1400 21,24 UC48 1200 35.0 24.8 13.00 11.00
TCGD42S41S1(H)
1200 - 1600 17,21 FC/MC/PC43 1400 42.0 29.2 13.00 11.00
1200 - 1600 21,24 FC/MC/PC48 1400 42.0 29.2 13.00 11.00
1200 - 1600 21 HC42 1400 42.0 29.2 13.00 11.00
1200 - 1600 21,24 UC48 1400 42.0 29.2 13.00 11.00
TCGD48S41S1(H)
1400 - 1800 21,24 FC/MC/PC48 1600 48.0 34.4 13.00 11.00
1400 - 1800 21,24 FC/MC/PC60 1600 48.0 34.4 13.00 11.00
1400 - 1800 24 HC60 1600 48.0 34.4 13.00 11.00
1400 - 1800 21,24 UC48 1600 48.0 34.4 13.00 11.00
1400 - 1800 21,24 UC60 1600 48.0 34.4 13.00 11.00
TCGD60S41S1
1600 - 2000 21,24 FC/MC/PC60 1800 57.0 38.5 13.00 11.00
1600 - 2000 24 FC/MC62 1800 57.0 38.5 13.00 11.00
1600 - 2000 24 HC60 1800 57.0 38.5 13.00 11.00
1600 - 2000 21,24 UC60 1800 57.0 38.5 13.00 11.00
1. Requires a 2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.
** Refer to Quick Selection Chart for specific furnace match-up.