Intex Recreation Krystal Clear Filter Pump Water Pump User Manual


 
110
SAVE THESE INSTRUCTIONS
Page 9
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007
OOPPEERRAATTIINNGG IINNSSTTRRUUCCTTIIOONNSS
FILTER CARTRIDGE CLEANING OR REPLACEMENT
1. Make sure the filter pump switch is "OFF". The switch is located on the motor
housing.
2. Connect the power cord to a GFCI protected electrical outlet.
It is recommended that the filter cartridge be replaced at least
every 2 weeks.
1. Make sure the filter pump is turned off, and disconnect the power cord from the
electrical outlet.
2. Grasp a plunger valve handle. Turn the handle counter-clockwise, push down
until it stops and then turn it clockwise until the plastic protruding notch anchors
in the "0/1" position. Repeat for the 2nd plunger valve. This prevents the water
from flowing out of the pool.
3. Gently turn the top air release valve 1-2 turns in a counter-clockwise direction.
This will allow the housing cover to be easily removed.
4. In a counter-clockwise direction remove the filter housing collar (1). Place it in a
safe location.
5. Remove the housing cover (4).
3. Grasp a plunger valve handle. Turn the handle counter-clockwise, pull up until
it stops, and then turn it clockwise until the metal protruding notch anchors in
the "0/1" position. Repeat for the 2nd plunger valve. This opens the valves to
allow water to flow into the filter pump.
4. With water flowing into filter pump, the water pressure will allow the air trapped
inside to escape from the air release valves (2 & 7). When all the air has
escaped water will flow out of the valves (2 & 7). When this occurs gently finger
tighten the valves (2 & 7) in a clockwise direction.
5. Turn the switch "ON". The filter pump is now filtering the water.
6. Operate the filter pump until the desired water clarity is obtained.
To prevent air lock, open the lower plunger valve (connected inlet hose)
first and then the upper plunger valve (connected outlet hose). Open air
release valves, wait until water starts to flow out of the air release valves,
close air release valves.
IMPORTANT
Risk of electric shock. Connect this product only to a grounding type
receptacle protected by a ground-fault circuit interrupter (GFCI) or residual
current device (RCD). Contact a qualified electrician if you cannot verify
that the receptacle is protected by a GFCI/RCD. Use a qualified electrician
to install the GFCI/RCD, which has a maximum rate of 30mA. Do not use a
portable residual current device (PRCD).
WARNING
OPERATING INSTRUCTIONS