Ingersoll-Rand 666DXXXC Heat Pump User Manual


 
TROUBLE SHOOTING
DIMENSIONAL DA
TA
(Dimensions shown are for reference only, they are displayed in inches and millimeters (mm).
11.500
(292 mm)
24-3/4
(629 mm)
19-7/8
(505 mm)
13-1/4
(337 mm)
2'' 14-1/2 NPT
666D0X-,D1X-
10-7/8
(276 mm)
3-3/8
(86 mm)
PN 97999-068
12
(305 mm)
AIR INLET
1/2-14N.P.T.
13/32 SLOT
(10 mm)
MATERIAL
OUTLET
FIGURE 4
2'' 14 BSP
666D2X-,D3X-
10
(254 mm)
EXHAUST
3/4-14 N.P.T.
MATERIAL
INLET
12-7/8
(327 mm)
INSTALLATION NOTE: THIS IS A DOWN-FLOWING PUMP, THE MATERIAL INLET IS ON THE TOP OF THE PUMP
666DXX-X-
C
PAGE 8 OF 8
Product discharged from exhaust outlet.
S Check for diaphragm rupture.
S Check tightness of diaphragm nut.
Air bubbles in product discharge.
S Check connections of suction plumbing.
S Check ``O"rings between intake manifold an fluid caps.
S Check tightness of diaphragm nut.
Low output volume, erratic flow, or no flow.
S Check air supply.
S Check for plugged outlet hose.
S Check for kinked (restrictive) outlet material hose.
S Check for kinked (restrictive) or collapsed inlet material hose.
S Check for pump cavitation - suction pipe should be sized at least
as large as the inlet thread diameter of the pump for proper flow if
high viscosity fluids are being pumped. Suction hose must be a
non - collapsing type, capable of pulling a high vacuum.
S Check all joints on the inlet manifolds and suction connections.
These must be air tight.
S Inspect the pump for solid objects lodged in the diaphragm chamĆ
ber or the seat area.