EXCESSIVE AIR PRESSURE
STATIC SPARK
HAZARDOUS MATERIALS
HAZARDOUS PRESSURE
WARNING
EXCESSIVE AIR PRESSURE. Can cause per-
sonal injury, pump damage or property damage.
Be sure material hoses and other components are able to
withstand uid pressures developed by this pump. Check all
hoses for damage or wear. Be certain dispensing device is
clean and in proper working condition.
Do not exceed the maximum inlet air pressure as stated on
the pump model plate.
WARNING
STATIC SPARK. Can cause explosion resulting
in severe injury or death. Ground pump and pumping
system.
Sparks can ignite ammable material and vapors.
The pumping system and object being sprayed must be
grounded when it is pumping, flushing, recirculating or
spraying flammable materials such as paints, solvents,
lacquers, etc. or used in a location where surrounding atmo-
sphere is conducive to spontaneous combustion. Ground the
dispensing valve or device, containers, hoses and any object
to which material is being pumped.
Secure pump, connections and all contact points to avoid vi-
bration and generation of contact or static spark.
Consult local building codes and electrical codes for spe-
cic grounding requirements.
After grounding, periodically verify continuity of electrical
path to ground. Test with an ohmmeter from each compo-
nent (e.g., hoses, pump, clamps, container, spray gun, etc.)
to ground to insure continuity. Ohmmeter should show 0.1
ohms or less.
Submerse the outlet hose end, dispensing valve or device
in the material being dispensed if possible. (Avoid free
streaming of material being dispensed.)
Use hoses incorporating a static wire.
Use proper ventilation.
Keep inflammables away from heat, open flames and
sparks.
Keep containers closed when not in use.
WARNING
Pump exhaust may contain contaminants.
Can cause severe injury. Pipe exhaust away from work area
and personnel.
In the event of a diaphragm rupture, material can be forced
out of the air exhaust muer.
Pipe the exhaust to a safe remote location when pumping
hazardous or inammable materials.
Use a grounded 3/8” minimum i.d. hose between the pump
and the muer.
WARNING
HAZARDOUS PRESSURE. Can result in serious
injury or property damage. Do not service or clean pump,
hoses or dispensing valve while the system is pressurized.
Disconnect air supply line and relieve pressure from the
system by opening dispensing valve or device and / or
carefully and slowly loosening and removing outlet hose or
piping from pump.
WARNING
HAZARDOUS MATERIALS. Can cause serious
injury or property damage. Do not attempt to return
a pump to the factory or service center that contains
hazardous material. Safe handling practices must comply
with local and national laws and safety code requirements.
Obtain Material Safety Data Sheets on all materials from
the supplier for proper handling instructions.
WARNING
EXPLOSION HAZARD. Models containing
a lu mi nu m we tt ed p ar ts c an no t b e us ed w it h
1,1,1-trichloroethane, methylene chloride or other
halogenated hydrocarbon solvents which may react and
explode.
Check pump motor section, fluid caps, manifolds and all
wetted parts to assure compatibility before using with sol-
vents of this type.
CAUTION
Verify the chemical compatibility of the pump
wetted parts and the substance being pumped, flushed
or recirculated. Chemical compatibility may change with
temperature and concentration of the chemical(s) within
the substances being pumped, flushed or circulated.
For specific fluid compatibility, consult the chemical
manufacturer.
CAUTION
Maximum temperatures are based on
mechanical stress only. Certain chemicals will signicantly
reduce maximum safe operating temperature. Consult
the chemical manufacturer for chemical compatibility and
temperature limits. Refer to PUMP DATA on page 1 of this
manual.
CAUTION
Be certain all operators of this equipment
have been trained for safe working practices, understand
it’s limitations, and wear safety goggles / equipment when
required.
CAUTION
Do not use the pump for the structural
support of the piping system. Be certain the system
components are properly supported to prevent stress on
the pump parts.
Suction and discharge connections should be flexible con-
nections (such as hose), not rigid piped, and should be com-
patible with the substance being pumped.
CAUTION
Prevent unnecessary damage to the pump.
Do not allow pump to operate when out of material for
long periods of time.
Disconnect air line from pump when system sits idle for
long periods of time.
CAUTION
Use only genuine ARO replacement parts to
assure compatible pressure rating and longest service life
.
NOTICE
Replacement warning labels are available
upon request: “Static Spark PN \ 93122 & Diaphragm
Rupture PN \ 93616-1.”
NOTICE
RE-TORQUE ALL FASTENERS BEFORE
OPERATION. Creep of housing and gasket materials may
cause fasteners to loosen. Re-torque all fasteners to insure
against uid or air leakage
.
WARNING
=
Hazards or unsafe practices which
could result in severe personal injury,
death or substantial property damage.
CAUTION
= Hazards or unsafe practices which
could result in minor personal in-
jury, product or property damage.
NOTICE
= Important installation, operation or
maintenance information.
OPERATING AND SAFETY PRECAUTIONS