Ingersoll-Rand 66615X-X-C Water Pump User Manual


 
Page 3 of 866615X-X-C (en)
GENERAL DESCRIPTION
The ARO diaphragm pump offers high volume delivery even at low air
pressure and a broad range of material compatibility options available.
Refer to the model and option chart. ARO pumps feature stall resistant
design, modular air motor / fluid sections.
Air operated double diaphragm pumps utilize a pressure differential in
the air chambersto alternately createsuction and positive fluidpressure
in the fluid chambers, valve checks insure a positive flow of fluid.
Pump cycling will begin as air pressure is applied and it will continue to
pump and keep up with the demand. It will build and maintain line pres-
sure and will stop cycling once maximum line pressure is reached (dis-
pensing device closed) and will resume pumping as needed.
AIR AND LUBE REQUIREMENTS
WARNING
EXCESSIVE AIR PRESSURE. Can cause pump
damage, personal injury or property damage.
S A filter capableoffiltering outparticles largerthan 50 micronsshould
be used ontheair supply. There isno lubrication required otherthan
the “O” ring lubricant which is applied during assembly or repair.
S If lubricatedairispresent,makesure thatit iscompatible withthe “O”
rings and seals in the air motor section of the pump.
OPERATING INSTRUCTIONS
S Always flush the pump with a solvent compatible with the material
being pumped if the materialbeing pumped is subject to “settingup”
when not in use for a period of time.
S Disconnect theair supply fromthe pump ifit istobe inactivefora few
hours.
S The outletmaterial volumeisgoverned notonly bythe air supply, but
also bythematerial supply availableat the inlet.The material supply
tubing should not be too small or restrictive. Be sure not to use hose
which might collapse.
S When the diaphragm pump is used in a forced-feed (flooded inlet)
situation, it is recommended that a “Check Valve” be installed at the
air inlet.
S Secure the diaphragm pump legs to a suitable surface to insure
against damage by vibration.
MAINTENANCE
Refer to the part views anddescriptions as provided on pages 4through
7 for parts identification and service kit information.
S Certain ARO “Smart Parts” are indicated which should be available
for fast repair and reduction of down time.
S Service kits are divided to service two separate diaphragm pump
functions: 1. AIR SECTION, 2. FLUID SECTION. The FLUID SEC-
TION is divided further to match typical part MATERIAL OPTIONS.
S Provide a clean work surface to protect sensitive internal moving
parts from contamination from dirtandforeign matter during service
disassembly and reassembly.
S Keep good records of service activity and include pump in preven-
tive maintenance program.
S Before disassembling, empty captured material in the outlet man-
ifold by turning the pump upside down to drain material from the
pump.
FLUID SECTION DISASSEMBLY
1. Remove top manifold(s).
2. Remove (22) balls, (19) “O” rings and (21) seats.
3. Remove (15) fluid caps.
NOTE: Only PTFE diaphragm models use a primarydiaphragm (7) and
a backup diaphragm (8). Refer to the auxiliary view in the Fluid Section
illustration.
4. Remove the (14) screws, (6) washers, (7) or (7 / 8) diaphragms and
(5) washers.
5. Remove (3) “O” rings.
NOTE: Do not scratch or mar the surface of (1) diaphragm rod.
FLUID SECTION REASSEMBLY
S Reassemble in reverse order.
S Clean and inspect all parts. Replace worn or damaged parts with
new parts as required.
S Lubricate (1) diaphragm rod and (2) “O” ring with Key-Lube “O” ring
lube.
S Use ARO pn/ 98931-T bullet (installationtool) to aid ininstallationof
(2) “O” ring on (1) diaphragm rod.
S Be certain (7) or (7 / 8) diaphragm(s) align properly with (15) fluid
caps before making final torque adjustments on bolt and nuts to
avoid twisting the diaphragm.
S For modelswithPTFE diaphragms: Item(8) Santoprene diaphragm
is installed with the side marked “AIR SIDE” towards the pump cen-
ter body. Install the PTFE diaphragm with the side marked “FLUID
SIDE” towards the fluid cap.
S Re-check torque settings after pump has been re-started and run a
while.
S VitonR and HytrelR are trademarks of theDuPont Company SKynarR is atrademark of Arkema Inc. SLoctiteR is aregistered trademark of Henkel Loctite Corporation S
S SantopreneR is aregistered trademark of Monsanto Company, licensed toAdvanced Elastomer Systems, L.P. SAROR is aregistered trademark of Ingersoll-Rand Company S