Cornelius 000 Fan User Manual


 
300381000
17
NOTE: When indicator on CO
2
cylinder regulator assembly 1800-psi gage is in shaded (‘ ‘change CO
2
cylinder’’) portion of the dial, CO
2
cylinder is almost empty and should be changed. CO
2
supply should
be checked daily and if necessary, replenished as instructed.
REPLENISHING SYRUP SUPPLY
Syrup supply should be checked daily and if necessary, replenished as instructed.
CLEANING AND SANITIZING
DAILY CLEANING
Perform daily cleaning of dispensing station as instructed in dispensing station Installation Instructions. Outside
of Cooling Unit must be cleaned periodically.
SANITIZING SYRUP SYSTEMS
Syrup systems should be sanitized every 90 days as instructed following Sanitizer Manufacturers
recommendations.
COOLING UNIT MAINTENANCE
COOLING UNIT EQUIPPED WITH CONDENSER COIL AND AIR INTAKE FILTER
CAUTION: Cooling Unit equipped with condenser coil is equipped with an air filter that
must be cleaned every 30 days as instructed. Circulating air, required to cool the coil, is
drawn in through air filter on back, and is exhausted out through coil on front of Unit.
Failure to clean and allowing air filter to become clogged, will cause refrigeration system to
overheat which will automatically shut refrigeration system down. After refrigeration system has
cooled down, system will automatically restart and operate until overheated and shut down again.
OPERATING COOLING UNIT IN THIS MANNER FOR PROLONGED PERIOD OF TIME COULD
RESULT IN COMPRESSOR FAILURE.
Area around Cooling Unit must be kept free of obstructions at all times for proper air circulation through the Unit.
Air filter must be cleaned every 30 days as instructed.
COOLING UNIT CARBONATOR MAINTENANCE
Lubrication
Carbonator water pump motor bearings must be oiled periodically as instructed.
Water Pump Yearly Maintenance (or After Water System Disruptions).
Carbonator water pump water strainer screen and liquid double check valve must be inspected and cleaned at
least once a year under normal circumstances and after any water system disruption (plumbing work,
earthquake, etc.). Inspect and clean water strainer screen and liquid double check valve as instructed.