classic HE - Users
2
INTRODUCTION
The classic HE is a wall mounted, room sealed, high efficiency
condensing boiler featuring full sequence automatic spark
ignition and fan assisted combustion.
Due to the very high efficiency, condensate is produced from
the flue gases and this is drained to a suitable disposal point
through the plastic waste pipe at the right lower rear of the
boiler. A condensate 'plume' will also often be visible at the flue
terminal.
SAFETY
Current Gas Safety (Installation & Use) Regulations or
rules in force.
In your own interest, and that of safety, it is the law that this
boiler must be installed by a CORGI registered installer.
In IE the installation must be carried out by a competent
person and installed in accordance with the current edition of
I.S. 813 “domestic Gas Installations”, the current Building
Regulations and reference should be made to the current ETCI
rules for electrical installation.
It is essential that the instructions in this booklet are strictly
followed, for safe and economical operation of the boiler.
ELECTRICITY SUPPLY
This appliance must be efficiently earthed.
Supply: 230 V ~ 50 Hz. The fusing should be 3A.
Connection must be made in a way that allows complete
isolation of the electrical supply such as a double pole switch
having a 3mm (1/8") contact separation in both poles, or a plug
and socket, serving only the boiler and system controls. The
means of isolation must be accessible to the user after
installation.
IMPORTANT NOTES
• This appliance must not be operated without the casing
correctly fitted and forming an adequate seal.
• If the boiler is installed in a compartment then the
compartment MUST NOT be used for storage purposes.
• The ventilation provided for the boiler during installation
MUST NOT be blocked, and a check should be made
periodically that the ventilation areas are free from any
obstruction.
• If it is known or suspected that a fault exists on the boiler
then it MUST NOT be used until the fault has been
corrected by a CORGI registered installer or in IE a
competent person.
• Under NO circumstances should any of the sealed
components on this appliance be used incorrectly or
tampered with.
• This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
• Children should be supervised to ensure that they do not play
with the appliance.
MINIMUM CLEARANCES
A clearance of 450mm (17 3/4") MUST be available at the front of
the boiler for servicing.
The minimum clearances given below MUST be complied with
in order to maintain the safe running of the boiler .
Above the boiler 100 mm (4")
At each side of the boiler 5 mm (
1/4")
Underneath the boiler 100 mm (4")
In front of the boiler 5 mm (1/4")
TO LIGHT THE BOILER. REFER TO FRAME 1
If a programmer is fitted, refer to separate instructions for the
programmer before continuing.
1. CHECK THAT THE ELECTRICITY SUPPLY TO THE BOILER
IS OFF.
2. Open the controls access door by hinging downwards.
3. Ensure that the gas inlet cock (D) is OPEN.
4. Press the overheat reset button (E), located as shown in
Frame 1.
5. Ensure that the mains on/off switch (C) is in the OFF position.
6. Switch ON the electricity supply to the boiler. Check that all
external controls, e.g. room thermostat etc., are ON.
7. Turn the boiler thermostat knob (B) to position 6 and the
mains on/off switch (C) to ON. After about 15 seconds the
boiler will light automatically - this can be viewed through the
sight glass (A).
Set the boiler thermostat to the desired position.
8. Close the controls access door.
In winter conditions, i.e. central heating and domestic hot water,
the thermostat should be set at position 5 or 6.
For summer conditions, i.e. domestic hot water only, the
thermostat should be set at position 3.
These settings, however, are offered for general guidance only
and other settings may be found preferable, dependent upon the
type of system installed or as recommended by the installer.
CAUTION. To avoid the possibility of injury during the installation, servicing or cleaning
of this appliance care should be taken when handling edges of sheet steel components
Destination Countries: GB, IE
classic HE
(Natural Gas Only)
HE9 G.C. Appliance No. 41-415-58
HE12 G.C. Appliance No. 41-415-59
HE15 G.C. Appliance No. 41-421-45
HE18 G.C. Appliance No. 41-421-46
201850-6.pmd 21/02/2008, 12:5850