HydroSurge 5600 Water System User Manual


 
6
Maintenance
Checking the Salt Level
Check the salt level monthly. Remove the lid from the cabinet or brine tank, make sure salt level is always above the
brine level (you should not be able to see water).
Adding Salt
Use only clean salt labeled for water conditioner use, such as crystal, pellet, nugget, button or solar.
The use of rock salt is discouraged because it contains insoluble silt and sand which build up in the brine tank and can
cause problems with the system’s operation. Add the salt directly to the tank, filling no higher than the top of the brine
well.
Caution
Liquid brine will irritate eyes, skin and open wounds - gently wash exposed area with fresh water. Keep children away
from your water conditioner.
Bridging
(Figure 7)
Humidity or wrong type of salt may create a cavity between the water and the salt. This
action, known as “bridging”, prevents the brine solution from being made, leading to your
water supply being hard.
If you suspect salt bridging, carefully pound on the outside of the brine tank or pour some
warm water over the salt to break up the bridge. This should always be followed up by
allowing the unit to use up any remaining salt and then thoroughly cleaning out the brine
tank.
Allow four hours to produce a brine solution, then manually regenerate the softener.
Care of Your Softener
To retain the attractive appearance of your new water softener, clean occasionally with mild soap solution. Do not use
abrasive cleaners, ammonia or solvents. Never subject your softener to freezing or to temperatures above 110°F (43°C).
Cleaning the Injector Assembly
(Figure 8)
Sediment, salt and silt will restrict or clog the injector. A clean water
supply and pure salt will prevent this from happening.
The injector assembly is located on the right side of the control valve.
This assembly is easy to clean.
Shut off the water supply to your softener and reduce the pressure by
opening a cold soft water faucet. Using a screwdriver, remove the two
screws holding the injector cover to the control valve body. Carefully
remove the assembly and disassemble as shown in Figure 8. The
injector orifice is removed from the valve body by carefully turning it
out with a large screwdriver. Remove the injector throat the same way.
Carefully flush all parts including the screen. Use a mild acid such as
vinegar or Pro-Rust Out to clean the small holes in the orifice and
throat.
Reassemble using the reverse procedure.
Resin Cleaner
An approved resin cleaner must be used on a regular basis if your water supply contains iron. The amount of resin cleaner
and frequency of use is determined by the quantity of iron in your water (consult your local representative or follow the
directions on the resin package).
Bridging
Figure 7
INJECTOR BODY
INJECTOR THROAT
INJECTOR NOZZLE
“O” RING
INJECTOR COVER
INJECTOR SCREEN
SCREW
Figure 8