Hunter,R.F EX5 4RJ Stove User Manual


 
Points regarding the ‘Fire-bed’
The stove is supplied with a ceramic matrix and coals/logs, which are to be
arranged by the fitter in strict accordance with the installation instructions. The
purchaser must not alter the layout of the coals/logs or add any extra coals/logs.
The coals/logs used in this stove to produce a realistic coal/log effect are made
from ceramic fibre based material. The ‘coals/logs’ may change colour after use,
which is quite normal.
Replacement ceramic matrices and coals/logs must be sourced from your
approved Hunter Stoves stockist.
I
MPORTANT NOTE:
It will take approximately 15-20 minutes for the firebed to take on its proper appearance
of glowing coals and yellow flames.
Operating the Appliance
It is strongly recommended that these instructions are read and thoroughly
understood in advance of operating this appliance.
Gas Control Cover Plate
To gain access to the gas control valve, the
valve cover plate must first be opened. Hold
the left-hand side of the cover and gently pull
outwards. The valve cover is secured in place
with a magnet.
Burner Controls
The gas control valve is situated on the left hand side of
the appliance, looking from the front, next to the front
left hand leg.
Pilot Assembly
The pilot assembly is positioned at the front
of the burner tray on the right hand side.
2
PILOT ASSEMBLY
GAS CONTROL VALVE