Hunter Fan UH68ODK Electric Heater User Manual


 
UH68 ODK/ODH Tent Heater
2-4
Operation Under Usual Conditions
Setup
Alaska Tent TEMPER Tent
Completely setup the Alaska tent, and deploy the duct collars at the end in which you are to
setup the heater. Make sure the generator or power supply is on line.
Before setting up the tent and heater, some thought should be given to the orientation of the
structures as to the prevailing wind direction. Try to orient the heater and shelter so the
exhaust is blown down range away from doors and shelter openings.
1. Move the UH68 ODK into position near the duct collars. Set up off ground using skid or
similar.
2. Open PUDA (1) and remove remote control(2) power cord(3) and inlet adapter(4).
3. Attach inlet adapter(4) to heater and attach return duct(5) using band clamp(6). Pay special
attention to airflow tag(7) on duct. DO NOT PUT RETURN DUCT ON BACKWARDS. This
will restrict incoming airflow.
4. Deploy PUDA(1) by tilting upwards and putting pins(8) in supports(9).
5. Attach supply duct(10) using band clamp(6). Pay special attention to airflow tag(7).
6. Pull ducts into tent and point heated air duct away from inlet duct, towards center of tent.
Pull heater away from tent until ducts are straight but not taught (12).
CAUTION
TWO PERSON LIFT
The UH68ODK weighs 130 Lbs. Attempting to lift
without proper personnel may cause serious injury
1
2
3
4