Hunter Fan Type A Models Fan User Manual


 
15
42890-01 • 02/18/10 • Hunter Fan Company
Problem: Nothing happens; fan does not move.
1. Turn power on, replace fuse, or reset breaker.
2. Loosen canopy, check all connections according to the wiring the
fan section.
3. Check the plug connection in the switch housing.
4. Push motor reversing switch rmly left or right to ensure that the
switch is engaged.
5. Pull the pull chain to ensure it is on.
6. Remove the shipping bumpers.
Problem: Noisy operation.
1. Tighten the blade bracket screws until snug.
2. Tighten the blade screws until snug.
3. Check to see if the blade is cracked. If so, replace all the blades.
4. Change to an approved speed control.
5. Be sure that the glass is secure.
6. Check and tighten the screws in the switch housing mounting
plate and in the upper and lower switch housing.
Problem: Excessive wobbling.
1. If your fan wobbles when operating, use the enclosed balancing kit
and instructions to balance the fan.
2. Tighten all blade and/or blade iron screws.
Problem: Lights dim when turned on or do not turn on
1. Check to make sure wattage of light bulbs installed match the
specications on the light socket.
9 • Troubleshooting
If you need parts or service assistance, please call
888-830-1326 (In Canada, call 866-268-1936) or
visit us at our Web site at
http://www.hunterfan.com.
Hunter Fan Company
7130 Goodlett Farms Parkway #400
Memphis, Tennessee 38016