Hunter Fan 44260 Thermostat User Manual


 
6
®
Reviewing Programs
To review your program settings, press
program
repeatedly to cycle through the programs.
You can also make changes at any time.
System Selector Switch
The System Selector switch on the front of the thermostat deter-
mines the operating mode of the thermostat. You may select
COOL, OFF, HEAT.
NOTE: Anytime you install or remove the thermostat from
the wallplate, slide the System Selector to the OFF posi-
tion to prevent the possibility of a rapid system On-Off.
Fan Switch
The Fan switch should normally be located in the AUTO position.
The Fan will be turned on along with normal operation of your
system. In a normal gas or oil furnace, the Fan will be turned on
by your furnace after its warm-up delay. For electric heat, air
conditioning, and heat pump operation, the Fan will turn on
with the system.
To run the Fan on continuously, slide the Fan switch to the ON position.
Temporary Manual Override
To temporarily change the current set temperature without affecting your program:
Press and hold for about 1 second
to enter Manual Override mode. When
display flashes, you can release the key.
Press again to change to your desired Set
Temperature. Hold the key for 2 seconds to
fast-advance the Set Temperature.
Press to return to normal mode, or wait 5
seconds for it to return automatically.
The current program number will flash to
signify the Temporary Override.
At the next program change time, the Tem-
porary Override is cancelled, and the next
program temperature becomes the setpoint
temperature.
To end the Temporary Manual Override:
Press, then press again. This will return the set temperature to the current
program set temperature.
Permanent Override
To hold your Manual Override for vacation or just an extended period of time:
Press to make the current program tem-
perature the HOLD temperature. HOLD
will be displayed on the LCD, and the
Program number
will disappear.
Follow the Temporary Manual Override
instructions above to change the Permanent
Manual Override temperature.
You can confirm the held set temperature by
pressing for less than 1 second.
To end the Permanent Manual Override:
Press again. The thermostat will return to the current program, and the HOLD
display will be canceled.
system
cool
heat
off
fan
on
auto
SET TEMP
3
COOL TEMP
PM
COOL TEMP
3
SA
or
or
hold
/return
hold
/return
hold
/return
TH
PM
HOLD
TEMP
hold
/return
Filter Monitor
Your thermostat measures the number of hours your heating and cooling system has been in
use. To maximize your system’s performance and energy efficiency, change or clean your filter
regularly.
When the total system runtime for heat
and cool reaches 400 hours, the Filter
Change Indicator will flash as a reminder
to check your system’s filter.
Press to review total filter usage. After 15
seconds, the display will return to normal
mode, or you can press the HOLD/RETURN
key to exit immediately.
After changing or cleaning the system’s
filter, press and hold the Filter Key for 3
seconds. The display will blink, and the
timer will be reset to zero.
SPAN Setting Mode
Your thermostat is set at the factory to cycle at 1˚F (0.5˚C) above and below the set tempera-
ture. (Span = 2) This setting has been designed to provide a comfortable room temperature
under most all conditions. However, if you find your system cycling too fast or too slow, then
the Span can be adjusted to modify the cycle time.
Press and hold BOTH for three seconds. The
display will flash, and SPAN will be dis-
played on the LCD.
Press to raise the Span to 3. This setting
INCREASES the cycle time by allowing your
system to run LONGER.
Press to lower the Span to 1. This setting
DECREASES the cycle time by causing your
system to run SHORTER.
The Span settings remain the same for both HEAT and COOL.
The Span can be changed at any time, and is independent of program times
or temperatures.
When batteries are installed in the thermostat, or the Reset key is pressed, the Span is reset
back to setting 2.
Backlighting (INDIGLO
®
Night-Light)
Your thermostat has an electroluminescent lamp that backlights the display for easy viewing
in the dark.
When any key is pressed or the System Switch is changed, the display is illuminated.
The display will remain illuminated for 5 seconds after the last key is pressed. This allows the
light to stay on if you need to operate several keys.
Note: If the thermostat is in Low Battery warning condition, the backlight will not
operate. Replace with 2 new alkaline batteries to restore the Backlight function.
Low Battery Warning
Your thermostat has a two-stage low battery warning sys-
tem. When the batteries are first detected to be weak, the
first stage low battery warning is indicated by battery symbol
flashing on the LCD display. At your earliest convenience, you
need to replace the batteries with 2 new AA alkaline batter-
ies.
When the batteries become too weak for normal operation,
the thermostat enters the second stage low battery warning
which shuts down the thermostat. In this condition, “BATT”
flashes alone on the display, and the thermostat will turn
your system Off. Your system will remain shut-off until the
batteries are replaced.
Note: The thermostat will still keep the current time and your programs in memory until
new batteries are installed. After confirming that new batteries have been inserted, the
thermostat will return to normal operation.
filter
TEMP
COOL
AM
PM
2
M T W TH F SA SU SET TEMP
FILTER
MIN
HR
T
PM
3
HEAT TEMP