Hunter Fan 43355 Thermostat User Manual


 
33
Details of Auto Recovery Operation:
Auto Recovery can be disabled by sliding the Re-
covery switch on the circuit board to the DISABLE
position. Refer to page 13.
Auto Recovery will not operate if Permanent hold,
Temporary hold or Home Today is in operation.
Auto Recovery can be canceled manually if HOLD/
RETURN is pressed during the recovery process. If a
recovery process is canceled manually then the re-
covery process will not start again until the next
program period starts (an exception is that if time
or program is changed then the thermostat will
check Auto Recovery conditions immediately).
Auto Recovery will be canceled and change to
Home Today mode if HOME TODAY is pressed
during the recovery process.
Auto Recovery will be canceled and change to
Temporary Manual Override mode if the setpoint
is adjusted during the recovery process.
If the system is changed between heat and cool
then the thermostat will recalculate Auto Recov-
ery again. Setpoint temperature will be changed
to the opposite system’s comfort temperature if
the recovery entry criteria are still met. Otherwise,
the recovery process will be canceled and return
to program control mode.