Hunter Fan 42122 Thermostat User Manual


 
44047-01 • 04/13/2010
18
6
Features
Menu Options
Example: If your thermostat is set to turn on at 72
O
in heat mode, with
a span setting of 2, your thermostat will activate your furnace at 71
O
and
shut it down when it reaches 73
O
. For cooling at 72
O
with a span of
2, your air conditioner will activate at 73
O
and shut down at 71
O
. This
setting can be changed to 1, 2, or 3. 1 will shorten your running time
while 3 will lengthen it.
5. SPAN 2: Unless you have a multi-stage conventional or heat pump
system, there is no need to change the second stage span. If you do,
use the or buttons to adjust between 1, 2, or, 3 degrees. Press
once this has been changed or if you need to make no changes.
Second stage span acts the same as your primary, but it determines
when and how long your second stage heat runs.
6. TEMP F/C: The thermostat can change your temperature reading
between Fahrenheit and Celcius. Use the or buttons to switch
between Fahrenheit (F) and Celsius (C) Press , the screen will ash
“Updated” and return to the home screen.