THERMOSTAT
1. Disconnect power from unit.
2. Remove access cover and locate thermostat.
3. Disconnect the two (2) control wires.
Wires
Capillary Tube
4. Remove capillary tube and bulb from thermowell in element. See previous page.
5. Remove mounting screw and knob.
6. Remove thermostat by sliding out from behind mounting bracket.
Mounting Bracket
Mounting Screw
7. Replace thermostat using the reverse procedure; refer to wiring diagram in Section II.