Hoover QS Quiet Carpet Cleaner User Manual


 
SECONDARY FILTER
To clean secondary filter
Disconnect cleaner from elec-
trical outlet.
The secondary filter protects the
motor from dirt particles. If the fil-
ter becomes dirty, either clean or
replace it. To remove secondary
filter, open cover of cleaner and lift
the filter from the top of the motor
housing. Clean filter by rinsing it in
water. When dry, slide secondary
filter back into place.
THE BELT
The belt in your power nozzle drives the agitator. It has been designed spe-
cifically for use in this cleaner and is important for effective operation.
There are other belts manufactured that are similar in shape and size but
are not designed for the HOOVER power nozzle. Such belts do not operate
the agitator correctly and may create stress which could damage your
power nozzle. Use only a genuine HOOVER Belt No.
38528-011
when a
belt replacement is necessary.
When to replace the belt on power nozzle
The belt, located under the nozzle cover, should be checked from time to
time to be sure it is in good condition.To check remove the nozzle cover
(see following section). If the belt is stretched or cut; or if the agitator fails
to rotate, replace the belt.
How to replace the belt
Disconnect cleaner from elec-
trical outlet and disconnect
power nozzle from extension
wands.
Turn nozzle over and unscrew the
2 Phillips head screws from the
nozzle base.