Honeywell VISTA-15P Home Security System User Manual


 
52
Summary of A/V Notifications (cont’d)
Alpha Display Keypads
SOUND CAUSE DISPLAY
LOUD,
INTERRUPTED*
Keypad & Ext.
FIRE ALARM.
FIRE is displayed; descriptor of zone in alarm is
displayed. If a fire alarm is manually activated,
zone number 95 will be displayed.
LOUD,
CONTINUOUS*
Keypad & Ext.
BURGLARY/AUDIBLE
EMERGENCY ALARM.
ALARM is displayed. If programmed, descriptor
of zone in alarm is also displayed
ONE SHORT
BEEP
(not repeated)
Keypad only
a. SYSTEM DISARM.
b. SYSTEM ARMING ATTEMPT
WITH AN OPEN ZONE.
c. BYPASS VERIFY.
a. DISARMED/READY TO ARM is displayed.
b. Number and descriptor of open protection zone
is displayed.
c. Numbers and descriptors of the bypassed zones
are displayed (One beep is heard for each zone
displayed). Then, the following is displayed:
DISARMED BYPASS /Ready to Arm.
ONE SHORT
BEEP
(about every 30
seconds)
Keypad only
a. SYSTEM IS IN TEST MODE.
b, LOW BATTERY AT A
TRANSMITTER.
c. SYSTEM WILL AUTOARM
WITHIN 10 MINUTES
a. Opened Zone identifications will appear.
b. LO BAT displayed with description of
transmitter.
c. No special display.
TWO SHORT
BEEPS
Keypad only
ARM AWAY or MAXIMUM.
ARMED AWAY or MAXIMUM displayed. Red
ARMED indicator lit.
THREE SHORT
BEEPS
Keypad only
a. ARM STAY, NIGHT-STAY,
OR INSTANT.
b. ZONE OPENED WHILE
SYSTEM IS DISARMED.
a. ARMED STAY or ARMED INSTANT
displayed. Red ARMED indicator lit.
b. CHIME displayed, descriptor of open
protection zone will be displayed if the [] key
is pressed.
RAPID
BEEPING
Keypad only
a. TROUBLE.
b. MEMORY OF ALARM.
c. SYSTEM LOW BATTERY.
d. EXT. SOUNDER WIRE FAIL.
e. LAST 10 SEC of EXIT DELAY
a. CHECK displayed. Descriptor of troubled
protection zone is displayed.
b. FIRE or ALARM is displayed; descriptor of
zone in alarm is displayed.
c. SYSTEM LO BAT displayed.
d. BELL FAILURE is displayed.
e. No special display.
SLOW
BEEPING
Keypad only
a. EXIT DELAY WARNING (if
programmed).
b. ENTRY DELAY WARNING.
a. ARMED AWAY or MAXIMUM is displayed
along with You May Exit Now.
b. DISARM SYSTEM OR ALARM WILL
OCCUR is displayed. Exceeding the delay
time without disarming causes an alarm.
* If a bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring.