Honeywell VISTA-128BPT Home Security System User Manual


 
RadioRA 2 Interfacing with Honeywell Vista-128BPT Security Systems Page 6
Table 2: Phantom Buttons and Recommended Programming
This table provides the recommended programming for each phantom button associated with security on the Main Repeater.
Button Type Recommended Programming
Phantom
Button
Security
System
Partition
Recommended
Scene
Lights Shades HVAC
Plug-in
Modules Time Clock
100 All
Single/Multi-
room scene
Emergency* Interior lights at 25% Open - - -
99 All Security mode Interior Full Interior lights at 100% Open - - -
98 All Security mode Exterior Flash Exterior lights flash - - - -
97 All
Reserved for
future use - - - - -
96 All
Reserved for
future use - - - - -
95 1
Single/Multi-
room scene Away Scene
Lights off (delayed off on exit
pathway) Close - Off -
94 1
Single/Multi-
room scene Welcome
Entry, foyer, kitchen lights on to
75% - - -
93 1
Single/Multi-
room scene
Goodnight Evening light levels Close Set Back Off -
92 1 Timeclock mode
Away Timeclock
Mode - - Set Back - Away Mode
91 1
Reserved for
future use - - - - -
90 2
Single/Multi-
room scene Away Scene
Lights off (delayed off on exit
pathway) Close - Off -
89 2
Single/Multi-
room scene
Welcome
Entry, foyer, kitchen lights on to
75%
- - -
88 2
Single/Multi-
room scene Goodnight Evening light levels Close Set Back Off -
87 2 Timeclock mode
Away Timeclock
Mode - - Set Back - Away Mode
86 2
Reserved for
future use - - - - -