Honeywell TH115-AF-GA Thermostat User Manual


 
TH115-AF-GA / TH115-AF-GB
21
ENGLISH
Display range: 0°C to 70.0°C (32°F to 158°F)
Ambient setpoint range (A/AF modes): 5.0°C to 30.0°C (40°F - 86°F)
Floor setpoint range (F mode): 5.0°C to 40.0°C (40°F - 104°F)
Floor limit range (AF mode): 5.0°C to 40.0°C (40°F - 104°F)
Resolution: 0.5°C (1°F)
Heating cycle length: 15 minutes
Data protection: In the event of a power failure, most settings are saved. However the time and Daylight
Saving Time must be set if the power failure lasts more than 6 hours. The thermostat will return to the
mode that was active prior to the power failure.
Technical Specifications
Model Supply
Max. load (resistive only) Ground Fault
Protection
(GFCI)
Wiring
Current Power
TH115-AF-GA
120 VAC, 60 Hz
15 A
1800 W
5 mA
4 wires,
double pole
240 VAC, 60 Hz 3600 W
TH115-AF-GB
120 VAC, 60 Hz 1800 W
15 mA
240 VAC, 60 Hz 3600 W
400-115-051-B (Honeywell TH115-AF-GA_GB) 5 x 3.125 EFS.book Page 21 Monday, April 12, 2010 3:10 PM