Honeywell TH115-AF-GA Thermostat User Manual


 
TH115-AF-GA / TH115-AF-GB
9
ENGLISH
Configuration switches are on the back of the faceplate.
Set the configuration switches
# Configurations Up Down
1 Display format °F / 12 h °C / 24 h
2
Early Start
1
1. Early Start is used in Automatic mode only. When Early Start is enabled (on), the thermostat determines when to start
heating so the Comfort temperature is attained at the beginning of periods 1 and 3. When Early Start is disabled (off),
heating starts only at the beginning of periods 1 and 3; thus there is a delay before the Comfort temperature is
reached.
Enable Disable
3
Temperature control mode
2
2. See page 3. To select the F Mode, place the switch in the F position. To select the AF Mode, place the switch in the AF
position and ensure that the temperature sensor is connected to the thermostat. To select the A Mode, place the switch in
the AF position and ensure that the remote temperature sensor is
NOT
connected to the thermostat.
FAF