Honeywell T8611M Thermostat User Manual


 
T8611M DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS
7 69-1415—1
IMPORTANT
Review the settings to confirm that they match
the system. Press Run Program to exit the
Installer Setup. The thermostat has saved the
Installer Setup changes and initiated a reset in
order to operate using the new settings. Be sure
to set the current day and time immediately.
Minimum off
time for the
compressor.
33 5 5 minutes
minimum off time
for the
compressor.
0 thru 4 Minimum number of minutes
(0 thru 5) the compressor is
off between calls for the
compressor.
Temperature
range stops in
heating.
34 90 Highest heating
setpoint setting.
40 to 89 Temperature range (1°F
increments) of heating
setpoint settings.
Temperature
range stops in
cooling.
35 45 Lowest cooling
setpoint setting.
46 to 99 Temperature range (1°F
increments) of cooling
setpoint settings.
Not Used. 36
Temperature
display
adjustment.
37 0 No difference in
displayed
temperature and
actual room
temperature.
-3 thru 3 1—Display adjusts to 1°F
higher than actual room
temperature.
2—Display adjusts to 2°F
higher than actual room
temperature.
3—Display adjusts to 3°F
higher than actual room
temperature.
-1—Display adjusts to -1°F
lower than actual room
temperature.
-2—Display adjusts to -2°F
lower than actual room
temperature.
-3—Display adjusts to -3°F
lower than actual room
temperature.
Furnace Air
Filter Timer.
43 2 30 days (System
run time)
0, 1, 3, 4 0 – off
1 – 10 days
3 – 60 days
4 – 120 days
(Time is counted when heat,
cool or fan running.)
Humidifier Pad
Monitor.
44 0 Off 1, 2, 3 1 – 90 days
2 – 180 days
3 – 365 days
(Time is counted by calendar
days in heat mode.)
Ultraviolet (UV)
Air Treatment
System Lamp
Monitor.
45 0 Off 1 1 – 365 days
(Time is counted by calendar
days in any mode.)
Table 3. Thermostat Installer Setup Options. (Continued)
Select
Installer Setup
Number (Press
Time key to
change)
Factory Setting
Other Choices
(Press s or t key to change)
Actual
SettingDisplay Description Display Description