T7200D,E, T7300D,E,F AND Q7300 SERIES 2000 PROGRAMMABLE COMMERCIAL THERMOSTATS AND SUBBASES
13 63-4355—4
IMPORTANT
Review the settings to confirm that they match the
system. Press Run Program to exit the Installer
Setup. The thermostat has saved the Installer Setup
changes and initiated reset in order to operate with
these new settings. Be sure to set the current day
and time immediately.
Setting Current Time/Day
1.
Press Set Current Day/Time.
NOTE: On initial power up or after an extended power
loss, 1:00 pm flashes on the display until a key
is pressed.
2.
Press Day until the current day is displayed.
NOTE: Sun = Sunday, Mon = Monday, Tue = Tuesday,
Wed = Wednesday, Thu = Thursday,
Fri = Friday, Sat = Saturday.
3.
Press increase
▲
or decrease
▼
key until the current
time is displayed.
NOTE: Tapping Set Current Day/Time changes the
time in one hour increments.
4.
Press Run Program.
INSTALLER SYSTEM TEST
Use the Installer System Test to check the thermostat
configurations and operation. Refer to Table 8 for a list of
available system tests. To start the system test:
CAUTION
Possible Equipment Damage.
Equipment damage can result if compressor is
cycled too quickly.
The minimum off time for compressors is bypassed
during the Installer System Test. Equipment damage
can occur if the compressor is cycled too quickly.
Press and hold both the increase
▲
and
decrease
▼
keys
until
10
appears. All segments of the LCD display for three
seconds before
10
appears. See Fig. 15 and 16.
Temperature
display adjustment.
37 0 No difference in displayed
temperature and actual room
temperature.
1 - 6 1: Display adjusts to 1°F (0.6°C) higher
than actual room temperature.
2: Display adjusts to 2°F (1.1°C) higher
than actual room temperature.
3: Display adjusts to 3°F (1.7°C) higher
than actual room temperature.
4: Display adjusts to 1°F (0.6°C) lower than
actual room temperature.
5: Display adjusts to 2°F (1.1°C) lower than
actual room temperature.
6: Display adjusts to 3°F (1.7°C) lower than
actual room temperature.
Minimum off-time
in heating.
38 4 4: 4-minute minimum off-time 0, 1, 2,
3, or 5
Minimum number of minutes (0 through 5)
the heating equipment is off between calls
for heat.
Not used. 39 — — — — —
Installer Setup
lockout (enable/
disable keypad
lockout using DIP
switch 1 on
thermostat back).
40 0 0: No Installer Setup lockout. 1 1: Installer Setup lockout activated.
Table 7. Thermostat Installer Setup Options. (Continued)
Select
Installer Setup
Number
(Press Unoccupied
Temp to change)
Factory Setting
Other Choices
(Press
▲
or
▼
to change)
Actual
SettingDisplay Description Display Description
a
Number 2 must be set to 1 to extend fan operation.
b
Number 22 must be set to 1 and remote sensor(s) must be installed.
M4951B
Set Current
Day/Time
Set Program Set Temperature Change
Time/Temp
Occupied
Temp
Unoccupied
Start Time Day
System Fan
Copy
Occupied
Start Time
Run
Program
Temporary
Occupied
Continous
Unoccupied
Set Current
Day/Time
Clear
Start Time
Unoccupied
Temp
Heat/Cool
Settings
Mon
PM
Set Day/Time
M4952B
Set Program Set Temperature Change
Time/Temp
Occupied
Temp
Unoccupied
Start Time Day
System Fan
Copy
Occupied
Start Time
Run
Program
Temporary
Occupied
Continous
Unoccupied
Set Current
Day/Time
Clear
Start Time
Unoccupied
Temp
Heat/Cool
Settings
Day
PM
Tue
Set Day/Time
M4953B
Set Program Set Temperature Change
Time/Temp
Occupied
Temp
Unoccupied
Start Time Day
System Fan
Copy
Occupied
Start Time
Run
Program
Temporary
Occupied
Continous
Unoccupied
Set Current
Day/Time
Clear
Start Time
Unoccupied
Temp
Heat/Cool
Settings
PM
Tue
Set Day/Time
M4954A
Set Program Set Temperature Change
Time/Temp
Occupied
Temp
Unoccupied
Start Time Day
System Fan
Copy
Occupied
Start Time
Run
Program
Temporary
Occupied
Continous
Unoccupied
Set Current
Day/Time
Clear
Start Time
Unoccupied
Temp
Heat/Cool
Settings
Auto
System Fan
Mon
Room
AM
Occupied 1
Heat
Run
Program