SDC / DHC Operation
EN2H-0220GE51 R0308 29
The last value to which the control device adjusted the heat
generator temperature appears as a recommendation.
Press button or button, to return to the last selected
operating mode.
Pos: 24 /156-Honeywell/Bedienung/Emmissionsmessung @ 1\mod_1207644670916_6.doc @ 9495
4.1.2.8.2 Emission measurement (not with district heating controllers)
ATTENTION
Emission measurements may only be carried out by the
chimney sweep.
Pressing the button controls the heat generator for a duration
of 20 min based on the set maximum temperature limit. The
remaining time is displayed and counted down.
With two-stage heat generators, both stages are in operation
(measurement at nominal output).
The heat generator is adjusted to the maximum heat generator
temperature. All heating circuits and the hot-water production
adjust their setpoint to the respective maximum temperature.
ATTENTION
There is a danger of scalding by hot water, as the hot-water
temperature can exceed the set setpoint temperature.
Emission measurement by the chimney sweep.
Emission measurement can be cancelled at any time with the
or
button.
Pos: 25 /156 -Honeyw ell/Bedi enung/H eizkurve @ 1\mod _120764 4424181_ 6.doc @ 9435
Cancellation
Function
Application
Cancellation