OPERATION (continued)
Model HZ-980 Series - MYEnergySmart™ Infrared Heater Operation
The heater has two operational modes – constant heating or
heating with an EnergySmart® thermostat control.
Turn heater on by pressing the Power Button ( ). The Power
Indicator will light and the heater will begin Powering Up,
as displayed in Status by a blinking light until the heater has
warmed up and the fan comes on. The heater will start in
the Constant High Heat mode and L3 will be displayed as the
Desired Temperature.
To set a Constant Heat Level, press the Thermostat Control
Buttons ( ):
- Choose L1 for constant Low
- Choose L2 for constant Medium
- Choose L3 for constant High
NOTE: Because the Low (L1) setting does not require as much electricity to operate, it is more energy ecient and may be a
better option if you are concerned about saving energy.
The Heating Energy Usage Indicator will always display the power consumption used by the heater at any time:
- If High, the heater is drawing 1500 watts to warm the room
- If Medium, the heater is drawing 1250 watts to warm the room or maintain the temperature
- If Low, the heater is drawing 1000 watts to warm the room or maintain the temperature
- If Fan, the heater is drawing only enough power to run the fan to cool the quartz elements
- If At Temp, the heater is drawing no power as the room has reached the Desired Temperature
To save up to 35% in energy bills
, set the EnergySmart® thermostat by pressing the Thermostat Control Buttons
( ) to choose a Desired Temperature between 60-85°. The EnergySmart® thermostat will automatically select the
appropriate power level to best accommodate your Desired Temperature. As the air temperature (Current Temp) in the room
approaches the Desired Temperature, the heater will automatically adjust the power consumption to provide consistent warmth
without wasting energy.
To override the EnergySmart® function, simply press The Thermostat Control Buttons ( ) to choose either Constant Low
(L1), Constant Med (L2) or Constant High (L3) Heat.
To set the Timer, press the Timer Button ( ) to select 1-8 hour setting. The heater will run for that chosen period in the selected
mode, counting down the hours and automatically shut o after the desired time has passed.
To save up to 25% in energy bills
, set the EnergySmart® thermostat by pressing the Thermostat Control Buttons
( ) and choose a Desired Temperature between 60-85°. The EnergySmart® thermostat will automatically select the
appropriate power level to best accommodate your Desired Temperature. As the air temperature (Current Temp) in the room
approaches the Desired Temperature, the heater will automatically adjust the power consumption to provide consistent warmth
without wasting energy.
To override the EnergySmart® function, simply press the Thermostat Control Buttons ( ) to choose either Constant Low
(L1) or Constant High (L2) Heat.
To set the Timer, press the Timer Button ( ) to select 2, 4, 6 or 8 hour setting. The heater will run for that chosen period in the
selected mode, counting down the hours and automatically shut o after the desired time has passed.
To shut the heater o, press the Power Button ( ) and the heater will begin Powering Down as displayed in Status by a
blinking light. The heater will automatically shut o in about 60 seconds after the fan cools the internal components.
1
2
3
4
5
6
7
8
9
Fig. 4
1. Status Indicators
2. Current Temperature Display
3. Power Indicator
4. Power Button
5. Desired Temperature Display
6. Timer
7. Energy Usage Indicator
8. MyTemp Settings
9. Thermostat Control Buttons
Model HZ-980 User Interface Controls: