Honeywell HE220 Humidifier User Manual


 
HE220, HE260 HUMIDIFIER AND INSTALLATION KIT
69-1645EF 4
Fig. 6. Installing the starter collar.
12. Remove liner to expose foam adhesive. Position
starter collar over opening.
13. Slide one end of the flexible ducting over the
starter collar and secure with one of the connecting
straps.
14. Insert the plain collar into the humidifier port and
secure with sheet metal screws. Connect the
flexible ducting over the collar and secure with a
connecting strap. See Fig. 7.
Fig. 7. Connecting bypass ducting.
15. Seal the duct connections with duct tape (not
included).
16. Reinstall the humidifier pad assembly in the humid-
ifier housing.
17. Hinge the cover in place and secure with the
thumbscrew located at the bottom of the cover.
Connecting the Plumbing
Use hot or cold water and either hard or softened water
in the humidifier.
1. Shut off the water.
CAUTION
Chemical Hazard.
Can cause personal injury or equipment
damage.
Do not use any line connected to an air
conditioner.
Do not use gas line.
2. Use the self-piercing saddle valve (included) to tap
into the water supply line at the location selected.
See Fig. 8. If tapping into galvanized pipe, drain
line and pre-drill 3/17 in. tap for saddle valve.
NOTE: The saddle valve is not designed to regulate
water flow. The valve is either open or closed.
IMPORTANT
To prevent debris from clogging the solenoid in-
line filter, be sure to install the saddle valve han-
dle pointing toward the ceiling.
Fig. 8. Installing the saddle valve.
3. Use 1/4 in. (6 mm) OD tubing and connect the sad-
dle valve to the inlet side of the solenoid valve on
the humidifier (see Fig. 9).
a. Place the brass compression nut over the
tubing.
b. Install brass insert into end of tubing.
c. Slide the plastic compression ring over the
tubing. (Discard copper compression ring pro-
vided with valve.)
NOTE: To prevent leaking, use plastic (Delrin) sleeve
rings with plastic tubing. Use copper sleeve
rings only with copper tubing.
d. Insert the tubing into the solenoid valve fitting
and support the valve while tightening the com-
pression nut.
NOTE: Do not over-tighten the compression nut. Mod-
erate tightness prevents leaking.
e. Repeat steps a. through d. for solenoid valve
fitting.
f. Secure tubing with clamps provided.
SUMMER
WINTER
M20173
M20785
PLAIN COLLAR
HUMIDIFIER PORT
M20175
SCREW DRIVER
WATER LINE