Application Considerations
The Honeywell F100 Media Air Cleaner is designed to work with gas, oil, and electric forced warm air furnaces
and with compressor cooling. It can also be used with heat pumps if the lter is changed regularly to prevent
excessive pressure drop. The F100 Media Air Cleaner is not recommended for applications where pressure drop
may be critical.
Models
F100F Media Air Cleaner includes cabinet, access door and pleated media lter. F100B Media Air Cleaner
includes cabinet and access door.
Air Conditioning
Mount the media air cleaner upstream of the evaporator coil in a cooling system. The lter will help to keep the
coil clean and reduce maintenance.
Humidiers
The media air cleaner is compatible with humidiers. Avoid applications where water mist will reach the media.
If an atomizing humidier is used, the lter media will require replacement more often because of minerals in the
water.
UV Lights
Germicidal UV lights can cause degradation of the media lter. The UV light should be located out of line of sight
or a minimum of 3 feet from the lter. Otherwise the lter may need to be replaced more frequently.