Honeywell DH150 Dehumidifier User Manual


 
TrueDRY DH150
7 69-2271EFS—01
Connect1/2-in.draintubetomaleconnectiondrain
outlet.Securedraintubetoconnectorwithhoseclamp.
Run drain hose continuously downhill to an approved
drain or condensate pump. Route to drain with a trap if
possible.
PlaceTrueDRYDH150onsupportsthatraisethebase
abovethetopflangesonthedrainpanbeneathit.
Raisingitwilloptimizedrainflowbygravity.
Plumbing
Terminal Descriptions
CAUTION: Low-voltage Hazard.
Cancauseequipmentdamage.
DisconnectHVACequipmentbeforebeginning
installation.
Afour-blockwiringterminalislocatedonthesloped
endofTrueDRYDH150.
* Note:OuterscrewssecureblocktoTrueDRY
DH150.Notforwiring.
DHUM:  Compressorandfanoperationfordehumidification.
R:  24Vhot
FAN: Fanactivationonlyforventilation.
C: 24Vcommon
Bend10in.roundflexducttofitovertheDH150ovaloutlet.
Ducting to Oval Outlet