3 69-2271EFS—01
InstallTrueDRYDH150accordingtoNationalElectricCodes.
Dimensions:
Specifications
Product weight:134lbs
Shipping weight:164lbs
Shipping dimensions:281/4in.Hx42in.Wx24in.D
Media Filter:MERV11,16in.Hx16in.Wx2in.D
Drain connection:3/4-in.threadedfemaleNPT
connection,withattached3/4-in.maleconnection.
Duct connections:Round10in.and6in.inlets.Oval
10in.x4in.outlet.
Cabinet:20gaugegalvanizedsteelpowder-coat
painted.
Input ratings
•Electricalinputvoltage:120VAC—1Phase—60Hz
nominal
•Inputcurrent:6.9amps
Output ratings
•Power transformer to R/C terminals:24VAC,
0.85A
•Energy Performance:3.6pintsperkilowatthour
(KWH).
Standards and approval body requirements
ETLtestedperULstandard474(ducteddehumidifier.)
Dry-Bulb
Temp
Wet-Bulb
Temp
Intake
Humidity
Capacity
(Pints/Day)
80°F 70°F 60%RH 150
70°F 61°F 60%RH 116
60°F 52°F 60%RH 88
Home Size
(square ft)
Dehumidifier Capacity Required to Maintain Desired Indoor RH*
60% RH Indoor (pints/day) 50% RH Indoor (pints/day) 40% RH Indoor (pints/day)
2080 49–54 55–58 71–78
2600 61–68 65–72 90–97
3120 75–82 79–86 95–110
*Basedonextremeclimateswhereoutdoorhumidityis70-90%RH.Forlessextremeclimates,largerhomescanbe
adequatelyservedwithlesscapacity.Actualrequirementsmayvary.
Airflow versus external static pressure
(0–1 in. water pressure) with collars attached
0in.WG 415CFM
0.4inWG. 365CFM
FRONT VIEW
6 DIAMETER
REAR VIEW
SIDE VIEW
37-1/2 (953) WITHOUT COLLARS
39-1/2 (1003) WITH COLLARS
19-15/16
(506)
20-5/8 (524)
10 DIAMETER
M27792
Insulation:Rvalue1
Compressor: Rotary-style
Refrigerant:2lb.,R-410.A
Operating Temp Range (outside cabinet):
56ºF-95ºF(13ºC-35ºC)
Operating Humidity Range: 0-99%RH