q Press and hold down , , and , simultaneously until the screen shows.
You now can change any of these settings.
Auxiliary Heat Type (Feature Number 5)
Auxiliary Heat options are:
3 = Hot water, high efficiency furnace (90% or better).
6 = Gas or oil forced air furnace (preset).
9 = Electric heat system.
To change your Auxiliary Heat type:
q Press until display shows your Auxiliary Heat type.
q Press Time to move to next feature or to return to main display.
Emergency Heat Type (Feature Number 7)
Emergency Heat options are:
3 = Hot water, high efficiency furnace (90% or better).
6 = Gas or oil forced air furnace.
9 = Electric heat system (preset).
To change your Emergency Heat type:
q Press until display shows your Emergency Heat type.
q Press Time to move to next feature or to return to main display.
Smart Response™ Technology (Feature Number 13)
Smart Response technology options are:
0 = Smart Response technology on (preset).
1 = Smart Response technology off.
To turn Smart Response technology on or off:
q Press once.
q Press Time to move to next feature or to return to main display.
NOTE: See Smart Response™ technology (page 20) for information about this feature.
M1870
4
FEATURE
NUMBER
OPTION
Run
Program
M1870
5
Run
Program
M1334
3
Run
Program