EVERYDAY
OPERATION
The two buttons are used when starting TrueSTEAM and to manually drain the tank.
Drain Button: Press and hold to drain water from the
TrueSTEAM tank. See “How do I clean the tank?” on
page 16.
When the Draining light is blinking, TrueSTEAM is
actively flushing water during a manual drain.
Go Button: Press to start or reset TrueSTEAM when
the Humidifying light is blinking.
Pressing and holding Go also clears the blinking
Service light and stops water draining from the tank.
Drain and Go Button: Pressing and holding both the
Drain and Go buttons in at the same time will interrupt
the water cooling cycle and immediately drain
the tank.
IMPORTANT: Pressing and holding the Drain and Go
buttons together—when the Draining light is already
on—causes TrueSTEAM to empty the tank, regardless
of water temperature. Make sure the drain outlet can
handle up to 212ºF (100ºC), or wait at least 45 minutes
to allow the water to cool before using
this feature.
CAUTION: Scalding Hazard.
Initial temperature of the drain water may be above 140°F (60°C) and can cause scalding injury.
Make sure the drain outlet is not exposed, and use caution when pressing the Drain button.