Honeywell 68-0308EFS-03 Air Cleaner User Manual


 
GETTING
STARTED
Application Considerations
Electrical Power / Airow Switch
The Honeywell Enhanced Air Cleaner should only be powered when airow is present.
FH8000A – These models are designed for use with an air handler and are equipped with an airow switch (see
Fig. 1), which provides power only when the air handler blower is operating. These models are designed to be
powered from a 208 to 230 VAC single phase power source.
M28899
Fig. 1. Airow Switch.
FH8000F – The furnace control EAC terminals provide power to the unit only when the furnace blower is
operating. These models are designed to be powered from the electronic air cleaner (EAC) terminals on a furnace
control board. If EAC terminals are not available, an alternative airow sensing mechanism such as the Honeywell
50027910-001 Differential Pressure Switch must be used to ensure the Honeywell Enhanced Air Cleaner is only
powered when airow is present. Contact your local Honeywell distributor for information on alternatives.
TrueCLEAN Enhanced Air Cleaner 68-0308EFS—03