Honeywell 68-0308EFS-03 Air Cleaner User Manual


 
WIRING
f. Attach the quick connect terminals to the furnace EAC-1 and EAC-2 spade connections, which are polarity
neutral.
g. Attach the ground ring to furnace chassis ground.
NOTE: The FH8000F Honeywell Enhanced Air Cleaner is to be powered by 120 VAC at 60 Hz.
NOTE: The Honeywell Enhanced Air Cleaner should only be powered when airow is present. The furnace
control EAC spade connections provide power only when the furnace blower is operating. If EAC
connections are not available, an alternative airow sensing mechanism such as the Honeywell
50027910-001 Differential Pressure Switch must be used to ensure the Honeywell Enhanced Air
Cleaner is only powered when airow is present. Contact a local Honeywell distributor for information on
alternative airow sensors.
Wiring the FH8000F (Furnace) Honeywell Enhanced Air
Cleaner
Before proceeding to Startup and Operation on page 19:
I wired the Honeywell Enhanced Air Cleaner as instructed.
FH8000F Wiring is complete. Go to page 19.
TrueCLEAN Enhanced Air Cleaner 68-0308EFS—03