Honeywell 504 Home Security System User Manual


 
14
Walk Test (User Level 5 and Above)
Purpose
The Walk Test option provides a method of testing the zones to
ensure that they are operating correctly. There are two options
available:
1. All zones can be tested
2. Selected zones can be tested
In both cases the sounder indicates an open zone. The test is recorded
in the log. Wire-free zones also show the received signal strength as a
percentage
Selecting Walk Test
Enter the QUICK MENU. Press the key 6 followed by the ent key. When
Walk Test is selected, Test All Zones or Selected Zones displays.
All Zones
Choosing All Zones (press key 1) starts the test immediately. No
selection is necessary as all valid zones are included in the test. The
sounder operates whenever a zone is opened and stops when all
zones are closed.
Note: The Test All Zones option only tests zones which can
be omitted from the system.
Selected Zones
Choosing the Selected Zones option by pressing key 2 displays the first
zone on the system. Each zone is displayed in turn by using the >A or
<B keys. When the zone to be included in the test is displayed, press the
# key. Other zones can be included in the test in the same manner. When
all of the required zones have been selected, press the ent key to start
the Walk Test.
Note: The Selected Zones option includes non-omittable
zones.
Ending Walk Test
To abort the walk test option press the esc key, otherwise the walk test
option remains active for 20 minutes after the last key press.