6 www.honeywell.com/sensing
Thermostats Line Guide
3150 Series 3153 Series 3156 Series 3200 Series
Description low silhouette hermetic low silhouette hermetic low level, silhouette hermetic aerospace
Amperage 2.0 A/1.0 A/2.0 A/2.0 A 2.0 A resistive 100 mA/500 mA 5.0 A resistive
Housing material
steel housing hermetically
sealed with glass-to-metal
seal at terminal junction
steel housing hermetically
sealed with glass-to-metal
seal at terminal junction
steel housing hermetically
sealed with glass-to-metal seal
at terminal junction
steel housing hermetically
sealed with glass-to-metal seal
at terminal junction
Operating temperature
-29 °C to 177 °C
[-20 °F to 350 °F]
-29 °C to 177 °C
[-20 °F to 350 °F]
-29 °C to 204 °C
[-20 °F to 400 °F]
-51 °C to 163 °C
[-60 °F to 325 °F]
Environmental exposure range
-54 °C to 260 °C
[-65 °F to 500 °F]
-65 °C to 260 °C
[-85 °F to 500 °F]
-62 °C to 260 °C
[-80 °F to 500 °F]
-65 °C to 177 °C
[-85 °F to 350 °F]
Dielectric strength
MIL-STD-202, Method 301;
750 Vac 60 Hz - Terminal
to Case
MIL-STD-202, Method 301;
1250 Vac 60 Hz - Terminal
to Case
MIL-STD-202, Method 301;
1250 Vac 60 Hz - Terminal to
Case
MIL-STD-202, Method 301;
1250 Vac
Insulation resistance
MIL-STD-202, Method 302;
Cond. B - 500 MOhm - 500
Vdc applied
MIL-STD-202, Method 302;
500 MOhm
MIL-STD-202, Method 302;
Cond. B - 500 MOhm - 500 Vdc
applied
MIL-STD-202, Method 302;
500 MOhm
Contact resistance
MIL-STD-202, Method 307;
0.050 Ohm
MIL-STD-202, Method 307;
0.050 Ohm max.
MIL-STD-202, Method 307;
0.050 Ohm
MIL-STD-202, Method 307;
0.025 Ohm max.
Hermetic seal
MIL-STD-202, Method 112;
Cond. 1 x 10-5
MIL-STD-202, Method 112;
Cond. C
MIL-STD-202, Method 112;
Cond. 1 x 10-5
MIL-STD-202, Method 112;
Cond. C
Moisture resistance MIL-STD-202, Method 106 MIL-STD-202, Method 106 MIL-STD-202, Method 106 MIL-STD-202, Method 106
Shock N/A
MIL-STD-202, Method 213;
100 G
N/A
MIL-STD-202, Method 213;
750 G
Vibration N/A
MIL-STD-202, Method 204;
20 G
N/A
MIL-STD-202, Method 204;
30 G: MIL-STD-202, Method
214; 50 G
Thermal shock N/A
MIL-STD-202, Method 107;
Cond. B
N/A
MIL-STD-202, Method 107;
Cond. B
Salt spray N/A
MIL-STD-202, Method 101;
Cond. B
N/A
MIL-STD-202, Method 101;
Cond. B
Acceleration N/A N/A N/A
MIL-STD-202, Method 212;
20 G
Precision
Thermostats