Honeywell 2450CM Thermostat User Manual


 
www.honeywell.com/sensing 5
3100 Series 3100U Series 3106 Series
Description hermetic UL-approved hermetic low level hermetic
Amperage 2.0 A/1.0 A/5.0 A/5.0 A 3.0 A resistive max. 100 mA/500 mA
Housing material
steel housing hermetically sealed with
glass-to-metal seal at terminal junction
steel housing hermetically sealed with
glass-to-metal seal at terminal junction
steel housing hermetically sealed with
glass-to-metal seal at terminal junction
Operating temperature -29 °C to 260 °C [-20 °F to 500 °F] -29 °C to 260 °C [-20 °F to 500 °F] -29 °C to 204 °C [-20 °F to 400 °F]
Environmental exposure range -62 °C to 288 °C [-80 °F to 550 °F] -62 °C to 288 °C [-80 °F to 550 °F] -62 °C to 260 °C [-80 °F to 500 °F]
Dielectric strength
MIL-STD-202, Method 301; 1250 Vac 60 Hz
- Terminal to Case
MIL-STD-202, Method 301; 1250 Vac
60 Hz - Terminal to Case
MIL-STD-202, Method 301; 1250 Vac
60 Hz - Terminal to Case
Insulation resistance
MIL-STD-202, Method 302; Cond. B - 500
MOhm - 500 Vdc applied
MIL-STD-202, Method 302; 50 MOhm
or MIL-STD-202, Method 302; Cond.
B - 500 MOhm - 500 Vdc applied
MIL-STD-202, Method 302; Cond. B -
500 MOhm - 500 Vdc applied
Contact resistance MIL-STD-202, Method 307; 0.050 Ohm
MIL-STD-202, Method 307; 0.050 Ohm
max.
MIL-STD-202, Method 307; 0.050
Ohm
Hermetic seal
MIL-STD-202, Method 112;
Cond. 1 x 10-5
MIL-STD-202, Method 112;
Cond. 1 x 10-5
MIL-STD-202, Method 112;
Cond. 1 x 10-5
Moisture resistance MIL-STD-202, Method 106 MIL-STD-202, Method 106 MIL-STD-202, Method 106
Shock N/A N/A N/A
Vibration N/A N/A N/A
Thermal shock N/A N/A N/A
Salt spray N/A N/A N/A
Acceleration N/A N/A N/A