NOTE: The air cleaner cannot be programmed unless it is plugged into the outlet.
T
o SET program points:
Press the SET button and hold for 3 seconds to activate time function. The SET
button will move through these programming functions:
Set (current) TIME.
Set PG1 cycle times P1-ON and P1-OFF.
Set PG2 cycle times P1-ON and P1-OFF, and P2-ON and P2-OFF.
Set EXIT mode and Run the clock.
T
o Customize the PG1 Program Settings to run ONE ON/OFF Cycle in a 24 hour
period:
NOTE: You are unable to set the OFF time to be the same as the ON time.
Press the SET button and hold for 3 seconds to activate time function. Move
through programming functions by repeatedly pressing SET button until PG1 and
P1-ON appear. The clock and program speed icons will appear (Fig. 4a).
Adjust the time using the hours and minutes button (up for hours, down for
minutes). This is the time that the machine will turn ON.
Adjust the desired speed setting using the SPEED button.
Press the SET button until PG1 and P1-OFF appear. The speed icon will disappear
(Fig. 4b).
Adjust the time using the hours and minutes button. This is the time that the
machine will turn OFF.
Repeatedly press SET button until ( ) disappears.
Press the PROGRAM button until PG1 appears. Unit will automatically operate per
your settings.
Customize Program Cycles
Fig. 4a
Fig. 4b
To run one pre-set program cycle in a 24 hour period (PG1).
PG1 Pre-Setting to run Program One
P1-ON 4 PM HIGH SPEED
P1-OFF 8 AM
To activate pre-set PG1, Press the PROGRAM button once. PG1 will be displayed.
Your machine is now programmed to run from 4pm to 8am on HIGH (Fig. 3a, 3b).
Pre-Set Program Cycle
Fig. 3a Fig. 3b