THEORY CUTAWAY
PFA/OV 003
Fan
Fuel
Filter
Air For Fuel
System
Air For Combustion
And Heating
Fuel
Spark
Plug
Combustion
Chamber
Intake
Air
Filter
Motor
Air Pump
Air Line
To Burner
Burner
Head
Nozzle
Fuel
Tank
Electronic
Ignitor
Cool
Air
In
Clean
Heated
Air Out
Output
Air
Filter
The Fuel System: An air pump is located on one end of the motor shaft. The
air pump forces air through the air line. The air is then pushed through the burner
head nozzle. The moving air causes fuel to be lifted from the tank. The fuel and air
mixture is sprayed into the combustion chamber in a fine mist.
The Air System: The motor turns a fan which pushes air into and around the
combustion chamber. This air is heated and provides a stream of clean, hot air.
The Ignition System: The electronic ignitor causes the spark plug to ignite the
fuel and air mixture.
The Flame-Out Control System: This system causes the heater to shut down
if the flame goes out.
THEORY OF
OPERATION
Figure 5 - Cross Section Operational View