Hobart ML-110301 FD3-150 ML-110305 FD3-200 ML-110309 FD3-300 Window User Manual


 
– 5 –
For an accessory group D installation, use the mounting flange (1, Fig. 3) included with accessory
group D. See Fig. 3 and the accessory group data sheet.
Fig. 2 Fig. 3
WARNING: HAZARDOUS MOVING PARTS — DO NOT
OPERATE DISPOSER UNTIL PROPERLY INSTALLED
TO CONE.
Use one of the following: Part No. 204006 or 204007
(15 inch diameter cone) or Part No. 204003 or 204004
(18 inch diameter cone). For custom-built installations
— minimum thickness of stainless steel cone shall be
.035 inches and minimum height of cone (vertical
distance from work surface to disposer sink flange)
shall be 6 inches (Fig. 4).
PLUMBING
WARNING: PLUMBING CONNECTIONS MUST
COMPLY WITH APPLICABLE SANITARY, SAFETY
AND PLUMBING CODES.
Fig. 4
Drain
The disposer is furnished with a waste discharge outlet flange (7, Fig. 5) threaded with a standard 2"
IPS tapered thread. Install waste lines with the shortest possible run and best fall. If possible, use a
fall of
1
/4" per foot. The waste exit must be lower than the waste outlet (see Fig. 2). The waste lines
must be thoroughly cleaned. Ream burrs from cut pipe ends and use fittings which will permit
unrestricted flow. Drum traps and grease traps must NOT be used.
6" Minimum
Disposer
Custom Built,
Locally Supplied
Cone
Countertop
Work Surface
PL-52467