MAINTENANCE (continued)
Maintenance of electric dust collector electrodes
Stop the operation with the remote controller
and unplug the power supply (or turn off the
circuit breaker).
Slowly open the vertical air deflectors using
both hands.
CAUTION
Be sure to open slowly using both hands as shown
in the illustration.
Otherwise, it may cause malfunction.
Do not use excessive force to move the air deflector
beyond the stopper located below it.
Otherwise, it may cause malfunction.
Remove the dirt on the electric dust collector
electrodes with a toothbrush.
Be sure to use a dry toothbrush.
Lightly brushed off the dust.
Horizontal air
deflectors
Electric dust collector electrodes
CAUTION
Do not touch the electric dust collector electrodes while the air conditioner is in operation
High voltage generated at these parts could result in electrical shock.
Do not splash or direct water to the electric dust collector electrodes
It may cause short circuit or malfunction.